A Novel Acoustic Uroflowmetry-Based Mobile App Voiding Diary: Comparison with Conventional Paper-Based Voiding Diary
Author(s) -
Jung Kwon Kim,
Hwanik Kim,
JinNyoung Ho,
Seong Jin Jeong,
Sangchul Lee
Publication year - 2022
Publication title -
biomed research international
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.772
H-Index - 126
eISSN - 2314-6141
pISSN - 2314-6133
DOI - 10.1155/2022/3390338
Subject(s) - nocturnal , polyuria , medicine , standard deviation , urination , urine , waist , urology , body mass index , urinary system , mathematics , statistics , endocrinology , diabetes mellitus
Objectives. To evaluate the usefulness of a novel acoustic uroflowmetry- (UFM-) based mobile application (app) voiding diary (VD) focusing on the (1) compliance and (2) correlation with a conventional paper-based VD. Materials and Methods. A total of 78 patients were included between December 2019 and June 2020, and a subsequent review of all data was performed. The analyzed data were as follows: (1) survey of convenience/satisfaction/preference comparing the two methods, (2) compliance regarding the completeness of both methods, and (3) correlation of each metric (24-hour urine volume, nocturnal urine volume, nocturnal polyuria index, total number of voids, number of daytime voids, number of nocturnal voids, and maximal bladder capacity) between the two methods. Results. The survey results of convenience, satisfaction, and preference were as follows. With regard to convenience and satisfaction area, higher scores are reported in the mobile app VD ( mean ± standard deviation (SD); convenience: 7.47 ± 2.19 [app] vs. 4.20 ± 2.49 [paper]; satisfaction: 7.36 ± 2.17 [app] vs. 5.07 ± 2.65 [paper]). The median score of the overall preference for using the mobile app instead of the paper-based VD was 9 out of 10 ( mean ± SD 7.82 ± 2.68 ). We also found a good correlation between the two methods for nocturnal urine volume ( r = 0.55 , p = 0.04 ), nocturnal polyuria index ( r = 0.66 , p = 0.23 ), total number of voids ( r = 0.9 , p = 0.02 ), number of nocturnal voids ( r = 0.83 , p = 0.02 ), and maximal bladder capacity ( r = 0.89 , p = 0.04 ). Conclusion. The acoustic UFM-based mobile app VD demonstrated favorable findings compared to the conventional paper-based VD.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom