z-logo
open-access-imgOpen Access
Lamotrigine Extraction and Quantification by UPLC-DAD in Plasma from Patients with Bipolar Disorder
Author(s) -
Claudia Verónica Palacios-Magaña,
Elba M. RomeroTejeda,
Nicte Selene Fajardo-Robledo,
Luis J. GonzálezOrtiz,
José G González-Mendez,
Fermín Paul PachecoMoisés
Publication year - 2022
Publication title -
international journal of analytical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.352
H-Index - 16
eISSN - 1687-8779
pISSN - 1687-8760
DOI - 10.1155/2022/3288646
Subject(s) - lamotrigine , chemistry , chromatography , protein precipitation , high performance liquid chromatography , acetonitrile , ethyl acetate , triethylamine , extraction (chemistry) , solid phase extraction , medicine , organic chemistry , psychiatry , epilepsy
A sensitive and efficient analytical process for detecting lamotrigine in acidic solution based in ultra-high-performance liquid chromatography-diode array detector (UPLC-DAD) was developed; the stationary phase used was a C8, 150 × 4.6 mm, 2.6 µm. The mobile phase consisted of acetonitrile/acidified water (0.01% H3PO4 and 0.005% triethylamine, pH 2.4) (25 : 75 v/v). Limits of detection and quantification were 0.02 µg/mL and 0.05 µg/mL, respectively. The working interval for the evaluation of the method ranged from 0.05 to 12 µg/mL, and the linear fit of the experimental data has a value of r2≥0.98. Before quantifying lamotrigine in plasma of patients with bipolar disorder, lamotrigine was released from plasma proteins with a 0.2 M sodium hydroxide solution, and then proteins were removed by precipitation with acetonitrile. Afterward, the lamotrigine base was dissolved in ethyl acetate. This extract was reconstituted in potassium phosphate solution (pH 2.4) to obtain more than 98% of lamotrigine protonated in N2, which was detected and quantified as indicated above. The absolute percentage of lamotrigine recovery is  ≥80% for all tested concentration levels. The accuracy and precision of the method have %CV values <4% for the lamotrigine levels of 3, 6, and 9 µg/mL. The correlation coefficient for the used concentration range is 0.99. The analytical method is precise and sensitive to measure lamotrigine levels expected in plasma of BD patients and these levels were in the therapeutic dose range.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom