z-logo
open-access-imgOpen Access
Nursing Analysis Based on Medical Imaging Technology before and after Coronary Angiography in Cardiovascular Medicine
Author(s) -
Qin Li,
Yangyang Yuan,
Guangyu Song,
Yonghua Liu
Publication year - 2022
Publication title -
applied bionics and biomechanics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.397
H-Index - 23
eISSN - 1754-2103
pISSN - 1176-2322
DOI - 10.1155/2022/3279068
Subject(s) - image fusion , norm (philosophy) , convolution (computer science) , artificial intelligence , medical imaging , computer science , image (mathematics) , pattern recognition (psychology) , mathematics , artificial neural network , political science , law
With the advancement of technology, medical imaging technology has been greatly improved. This article mainly studies the nursing before and after coronary angiography in cardiovascular medicine based on medical imaging technology. This paper proposes a multimodal medical image fusion algorithm based on multiscale decomposition and convolution sparse representation. The algorithm first decomposes the preregistered source medical image by NSST, takes the subimages of different scales as training images, and optimizes the subdictionaries of different scales; then convolution and sparse the subimages on each scale encoding to obtain the sparse coefficients of different subimages; secondly, the combination of improved L1 norm and improved spatial frequency (novel sum-modified SF (NMSF)) is used for high-frequency subimage coefficients, and the fusion of low-frequency subimages improved the rule of combining the L1 norm and the regional energy; finally, the final fused image is obtained by inverse NSST of the fused low-frequency subband and high-frequency subband. Experimental analysis found that the bifurcation angle has nothing to do with the damage of the branch vessels after the main branch stent is placed. The bifurcation angle greater than 50° is an independent predictor of MACE after stent extrusion for bifurcation lesions. Experimental results show that the proposed method has good performance in contrast enhancement, detail extraction, and information retention, and it improves the quality of the fusion image.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom