Dynamic Echocardiographic Imaging of a Valve-in-Valve Mitral Prosthesis
Author(s) -
Bishoy Wassef,
Mina Masry,
Mounir Ghali,
John N. Makaryus,
Amgad N. Makaryus
Publication year - 2022
Publication title -
case reports in radiology
Language(s) - English
Resource type - Journals
eISSN - 2090-6862
pISSN - 2090-6870
DOI - 10.1155/2022/1366037
Subject(s) - medicine , prosthesis , mechanical heart valve , mitral valve , heart valve , cardiology , mitral valve replacement , mechanical valve , valve replacement , surgery , cardiac valve , stenosis
Dynamic imaging of heart valves and specifically prosthetic valves is a central benefit of echocardiography. Most bioprosthetic heart valves degenerate over a given time and hence require repeat valve replacement which carries a significant risk of morbidity and mortality. Reoperation is the standard of care and may still be required after the first successful surgery due to complications disrupting either mechanical or bioprosthetic valves. Such complications can be delayed or even prevented if optimal prosthesis selection is individualized according to patients’ medical and postimplantation follow-up. We present the case of an 84-year-old woman where an open-heart valve-in-valve approach, implanting a mechanical valve in a failed bioprosthetic valve, produced a unique image on transthoracic echocardiography which needs to be recognized by imagers for appropriate patient diagnosis and management.