z-logo
open-access-imgOpen Access
Simplified Assessment of the Index of Microvascular Resistance
Author(s) -
Monika Kodeboina,
Sakura Nagumo,
Daniel Munhoz,
Jeroen Sonck,
Niya Mileva,
Emanuele Gallinoro,
Alessandro Candreva,
Takuya Mizukami,
Frederik Van Durme,
Alex Heyse,
Eric Wyffels,
Marc Vanderheyden,
Emanuele Barbato,
Jozef Bartúnek,
Bernard De Bruyne,
Carlos Collet
Publication year - 2021
Publication title -
journal of interventional cardiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.764
H-Index - 51
eISSN - 1540-8183
pISSN - 0896-4327
DOI - 10.1155/2021/9971874
Subject(s) - papaverine , medicine , reproducibility , adenosine , coronary artery disease , cardiology , microcirculation , vascular resistance , cardiac catheterization , anesthesia , hemodynamics , statistics , mathematics
Background To validate a simplified invasive method for the calculation of the index of microvascular resistance (IMR).Methods This is a prospective, single-center study of patients with chronic coronary syndromes presenting with nonobstructive coronary artery disease. IMR was obtained using both intravenous (IV) adenosine and intracoronary (IC) papaverine. Each IMR measurement was obtained in duplicate. The primary objective was the agreement between IMR acquired using adenosine and papaverine. Secondary objectives include reproducibility of IMR and time required for the IMR measurement.Results One hundred and sixteen IMR measurements were performed in 29 patients. The mean age was 68.8 ± 7.24 years, and 27.6% was diabetics. IMR values were similar between papaverine and adenosine (17.7 ± 7.26 and 20.1 ± 8.6, p =0.25; Passing-Bablok coefficient A 0.58, 95% CI −2.42 to 3.53; coefficient B 0.90, 95% CI −0.74 to 1.07). The reproducibility of IMR was excellent with both adenosine and papaverine (ICC 0.78, 95% CI 0.63 to 0.88 and ICC 0.93, 95% CI 0.87 to 0.97). The time needed for microvascular assessment was significantly shortened by the use of IC papaverine (3.23 (2.84, 3.78) mins vs. 5.48 (4.94, 7.09) mins, p < 0.0001).Conclusion IMR can be reliably measured using IC papaverine with similar results compared to intravenous infusion of adenosine with increased reproducibility and reduced procedural time. This approach simplifies the invasive assessment of the coronary microcirculation in the catheterization laboratory.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom