z-logo
open-access-imgOpen Access
Simultaneous Determination of Methamphetamine and Its Isomer N-Isopropylbenzylamine in Forensic Samples by Using a Modified LC-ESI-MS/MS Method
Author(s) -
Yangxu Luo,
Juan Du,
Xiao Huadi,
Ling Zheng,
Xuncai Chen,
Ande Ma,
Qizhi Luo
Publication year - 2021
Publication title -
journal of nanomaterials
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.463
H-Index - 66
eISSN - 1687-4129
pISSN - 1687-4110
DOI - 10.1155/2021/6679515
Subject(s) - detection limit , chromatography , formic acid , analyte , ammonium acetate , selected reaction monitoring , acetonitrile , materials science , analytical chemistry (journal) , chemistry , mass spectrometry , high performance liquid chromatography , tandem mass spectrometry
Accurate identification and quantification of methamphetamine (MA) and its related substances are essential for the investigation and fair trial of drug offenses. In this study, a modified LC-ESI-MS/MS method for the simultaneous determination of MA and its isomer N-isopropylbenzylamine (N-IBA) in forensic samples was developed and validated. Optimum chromatographic separation of the target analytes was achieved on an Agilent Poroshell 120 SB-C18 column (  mm, 2.7 μm) at 40°C with isocratic elution at the flow rate of 0.40 mL/min. The mobile phase was acetonitrile and 20 mM ammonium acetate solution containing 0.1% formic acid (80 : 20, ). Positive ESI-MS/MS detection was performed in multiple reaction monitoring (MRM) mode to identify and quantify the target analytes. Method validation showed excellent linearity in the range of 0.51 ng/mL~51 ng/mL for MA and N-IBA. The low limit of detection (LLOD) and low limit of quantification (LLOQ) reached 0.1 ng/mL and 0.3 ng/mL for both analytes. The method showed a satisfactory accuracy with an inter- and intraday-relative error (RE) <20%, and a precision of inter- and intraday relative standard deviation (RSD) less than 15%. The validated method was successfully applied in real forensic samples and resulted in the detection of MA and N-IBA in 8 suspected samples in drug cases that only deemed MA positive using our previous routine screening procedure, which avoided the misidentification of N-IBA as MA.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom