Dosimetry and Comparison between Different CT Protocols (Low Dose, Ultralow Dose, and Conventional CT) for Lung Nodules’ Detection in a Phantom
Author(s) -
Cleverson Alex Leitão,
Gabriel Lucca de Oliveira Salvador,
Priscilla Tazoniero,
Danny Warszawiak,
Cristian Saievicz,
Rosangela Requi Jakubiak,
Dante Luiz Escuissato
Publication year - 2021
Publication title -
radiology research and practice
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.125
H-Index - 5
eISSN - 2090-1941
pISSN - 2090-195X
DOI - 10.1155/2021/6667779
Subject(s) - imaging phantom , nuclear medicine , medicine , nodule (geology) , hounsfield scale , dosimeter , dosimetry , mcnemar's test , lung , radiology , computed tomography , mathematics , paleontology , statistics , biology
Background The effects of dose reduction in lung nodule detection need better understanding.Purpose To compare the detection rate of simulated lung nodules in a chest phantom using different computed tomography protocols, low dose (LD), ultralow dose (ULD), and conventional (CCT), and to quantify their respective amount of radiation.Materials and Methods A chest phantom containing 93 simulated lung nodules was scanned using five different protocols: ULD (80 kVp/30 mA), LD A (120 kVp/20 mA), LD B (100 kVp/30 mA), LD C (120 kVp/30 mA), and CCT (120 kVp/automatic mA). Four chest radiologists analyzed a selected image from each protocol and registered in diagrams the nodules they detected. Kruskal–Wallis and McNemar's tests were performed to determine the difference in nodule detection. Equivalent doses were estimated by placing thermoluminescent dosimeters on the surface and inside the phantom.Results There was no significant difference in lung nodules' detection when comparing ULD and LD protocols ( p =0.208 to p =1.000), but there was a significant difference when comparing each one of those against CCT ( p < 0.001). The detection rate of nodules with CT attenuation values lower than −600 HU was also different when comparing all protocols against CCT ( p < 0.001 to p =0.007). There was at least moderate agreement between observers in all protocols ( κ -value >0.41). Equivalent dose values ranged from 0.5 to 9 mSv.Conclusion There is no significant difference in simulated lung nodules' detection when comparing ULD and LD protocols, but both differ from CCT, especially when considering lower-attenuating nodules.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom