z-logo
open-access-imgOpen Access
Safety Evaluation and Flow Modification in the Anterior Cerebral Artery after Pipeline Embolization Device Deployment across the Internal Carotid Artery Terminus
Author(s) -
Chao Xu,
Pei Wu,
Jian-Yi Han,
Bowen Sun,
Chunlei Wang,
Shancai Xu,
Bin Luo,
Xinjian Yang,
Qingchun Mu,
Huaizhang Shi
Publication year - 2021
Publication title -
biomed research international
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.772
H-Index - 126
eISSN - 2314-6141
pISSN - 2314-6133
DOI - 10.1155/2021/6657595
Subject(s) - internal carotid artery , occlusion , medicine , univariate analysis , anterior communicating artery , aneurysm , embolization , blood flow , cardiology , radiology , multivariate analysis
Method The clinical and imaging data of PEDs in the postmarket multicenter registry study (PLUS) in China were retrospectively analyzed, and patients were divided into two groups on the basis of the follow-up angiographic results: group 1 (no significant change in A1 blood flow) and group 2 (A1 occlusion or decreased blood flow). We collected patients' baseline data and evaluated the following imaging indicators: diameter and ratio of bilateral A1, M1, and internal carotid artery (ICA) vessels before stenting and the ratio of the PED size (sPED) to the ipsilateral ICA (I-ICA) diameter on the implantation side.Results A total of 1171 patients were included, of whom 48 met the inclusion criteria (17 in group 1 and 31 in group 2). In group 2, three patients experienced neurological deterioration at follow-up. From the univariate analysis of outcomes, single PED without coils, incomplete aneurysm occlusion (IAO), maximum aneurysm diameter, aneurysms involving the ICA bifurcation (ICAb), and large sPED/I-ICA diameter ratio were included in the multivariate analysis ( P < 0.20). The multivariate regression analysis results showed that the ratio of sPED/I-ICA diameter was the factor influencing A1 vessel occlusion. The area under the ROC curve was 73.2%. When the sPED/I-ICA diameter ratio was 1.14, sensitivity was 70.6%, and specificity was 77.4%.Conclusion When an oversized PED is placed from M1 to the ICA, the higher porosity formed at the covered A1 orifice is conducive to maintaining stable A1 blood flow and reducing the risk of A1 vessel occlusion. This trial is registered with ClinicalTrials.gov identifier: NCT03831672 .

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom