z-logo
open-access-imgOpen Access
Changes in Intraocular Pressure after Transepithelial Photorefractive Keratectomy and Femtosecond Laser In Situ Keratomileusis
Author(s) -
Chien-Chih Chou,
PoJen Shih,
Hung-Chou Lin,
Junpeng Chen,
JiaYush Yen,
IJong Wang
Publication year - 2021
Publication title -
journal of ophthalmology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.818
H-Index - 40
eISSN - 2090-0058
pISSN - 2090-004X
DOI - 10.1155/2021/5592195
Subject(s) - keratomileusis , medicine , photorefractive keratectomy , ophthalmology , femtosecond , intraocular pressure , in situ , laser , cornea , optics , physics , meteorology
Purpose To investigate the changes in intraocular pressure (IOP) and biomechanically corrected IOP (bIOP) in patients undergoing transepithelial photorefractive keratectomy (TPRK) and femtosecond laser in situ keratomileusis (FS-LASIK) and to determine the effects of preoperative biomechanical factors on IOP and bIOP changes after FS-LASIK and TPRK.Design A retrospective comparative study.Methods We retrospectively investigated the IOP and corneal biomechanical changes in 93 eyes undergoing FS-LASIK and 104 eyes undergoing TPRK in a clinical setting. Preoperative and postoperative data on ophthalmic and Corvis ST examinations, in vivo Young's modulus, and noncontact tonometry were analyzed. Marginal linear regression models with generalized estimating equations were used for intragroup and intergroup comparisons of IOP and bIOP changes.Results In the univariate model, IOP reduction after FS-LASIK was 2.49 mmHg higher than that after TPRK. In addition, bIOP reduction after FS-LASIK was 1.85 mmHg higher than that after TPRK. In the multiple regression model, we revealed that IOP reduction after FS-LASIK was 1.75 mmHg higher than that after TPRK. Additionally, bIOP reduction after FS-LASIK was 1.64 mmHg higher than that after TPRK. Postoperative changes in bIOP were less than those in IOP. In addition, Young's modulus and CBI had no significant effect on postoperative IOP and bIOP changes. We establish a biomechanically predictive model using the available data to predict postoperative IOP and bIOP changes after TPRK and FS-LASIK.Conclusions Reductions in IOP and bIOP after FS-LASIK were 1.75 mmHg and 1.64 mmHg, respectively, more than those after TPRK, after adjustment for confounders. We revealed that the type of refractive surgery and peak distance (PD) were significant predictors of postoperative IOP and bIOP changes. By contrast, depth of ablation showed a significant effect on only IOP changes.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom