z-logo
open-access-imgOpen Access
Effect of Using a Plastic Stent with Apically Repositioned Flap in Peri-Implant Soft Tissue Augmentation: A Randomized Controlled Clinical Trial
Author(s) -
Ahmed Hamdy,
Hala Kamal Abd El Gaber,
Dalia Ghalwash,
Waleed Abbas
Publication year - 2021
Publication title -
international journal of dentistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.61
H-Index - 33
eISSN - 1687-8736
pISSN - 1687-8728
DOI - 10.1155/2021/5590400
Subject(s) - medicine , stent , dentistry , abutment , implant , statistical significance , soft tissue , buccal administration , buccal mucosa , peri , randomized controlled trial , surgery , orthodontics , oral cavity , civil engineering , engineering
Objectives This study aimed to clinically assess and compare the width of peri-implant keratinized mucosa following the use of a readymade plastic stent with apically repositioned flap versus conventional apically repositioned flap with papillary sparing incisions during single-stage implant placement protocol.Materials and Methods A total of 20 patients were enrolled in this study. In the test group, a prefabricated implant-retained stent was clipped on the healing abutment after implant surgery to reposition the keratinized tissue buccoapically. In the control group, simple interrupted sutures were applied instead of using a stent. After the surgical procedure, the width of the buccal keratinized mucosa was measured at the mesial, middle, and distal aspects of the healing abutment. The change in the width of the buccal keratinized mucosa was assessed at 3 months and 6 months.Results No statistically significant difference was found between the stent group and control group in 6 months' interval where p =0.840, where both groups showed the same mean value of 4.70 ± 0.35 and 4.70 ± 0.63, respectively. The percent of change in the width of KM was found to be higher in the stent group than in the control group with no statistical significance.Conclusion The use of a readymade plastic stent in combined full/partial-thickness apically repositioned flap shows to be effective in increasing the width of KM compared to the conventional technique. This trial is registered with NCT03754894 .

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom