z-logo
open-access-imgOpen Access
VEILND (Video Endoscopic Inguinal Lymph Node Dissection) with Florescence Indocyanine Green (ICG): A Novel Technique to Identify the Sentinel Lymph Node in Men with ≥pT1G2 and cN0 Penile Cancer
Author(s) -
Milan Hora,
Ivan Trávníček,
Š. Nykodýmová,
Jiří Ferda,
Denisa Kacerovská,
Květoslava Michalová,
Ondřej Hes,
Suks Minhas
Publication year - 2021
Publication title -
contrast media and molecular imaging
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.714
H-Index - 50
eISSN - 1555-4317
pISSN - 1555-4309
DOI - 10.1155/2021/5575730
Subject(s) - medicine , indocyanine green , penile cancer , sentinel lymph node , dissection (medical) , surgery , lymph , sentinel node , lymph node , penis , biopsy , radiology , penectomy , cancer , breast cancer , pathology
In men with ≥pT1G2 cN0, penile cancer lymph node sampling is recommended with either (1) scintigraphically labelled Dynamic sentinel lymph node biopsy (DSLNB) or (2) modified inguinal lymph node dissection (MILND). Although DSLNB is a minimally invasive technique, the false negative rate can be about 10%, and a further operative procedure is required if positive. Open MILND is a diagnostic and therapeutic option but has a much higher morbidity. A potential compromise is the technique of LND-VEILND (video endoscopic inguinal LND) that can be combined with ICG florescence marking of sentinel lymph node (SLN). We present a pilot study of ICG-VEILND. The aim was to validate the applicability of a combination ICG marking of SLN in VEILND (to increase probability to excise SLN) and determine the optimal timing and dosage of ICG.Materials and Methods 15 patients with VEILND (24 groins) underwent ICG application with fluorescence near-infrared (NIR 803⟶830 nm) detection. ICG is applied subcutaneously adjacent to the penile cancer or residual stump of penis or suprapubic region (in a history of total penectomy: 5 cases). The dose of 1.25 mg (ICG) was applied in one case with invisible SLN, the dose of 2.5 mg in 1 mL in 8 cases, and 5 mg in the remaining 6 patients (10 groins).Results Failure of marking SLN with ICG occurred in 25.0% of cases (6/24): due to application of 1.25 mg ICG, extensive metastasis to SLN, in 4 cases, the cause was unknown (16.7%, 4/24). In the short follow-up period, no local recurrence was seen in the pN0 ICG group.Conclusion Fluorescence infrared image with ICG dye increases the probability of removal of the SLN during VEILND. The dose of ICG is 2.5 (5) mg diluted in 1 ml and can be applied preoperatively even in the suprapubic region in men with a history of total penectomy, with an unexplainable failure of ICG marking in 16.7%.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom