z-logo
open-access-imgOpen Access
A RP-HPLC Method for the Analysis of Neostigmine Methylsulfate and Process-Related Impurities, Forced Degradation Studies, in the Injection Formulation
Author(s) -
Manali Parab,
Vaishali Shirsat,
Yogita M. Kodgule,
Mandar Kodgule
Publication year - 2021
Publication title -
international journal of analytical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.352
H-Index - 16
eISSN - 1687-8779
pISSN - 1687-8760
DOI - 10.1155/2021/5570173
Subject(s) - neostigmine , chemistry , forced degradation , impurity , chromatography , acetonitrile , high performance liquid chromatography , degradation (telecommunications) , reversed phase chromatography , organic chemistry , anesthesia , medicine , telecommunications , computer science
Neostigmine methylsulfate is an anticholinesterase agent and is clinically used for treating myasthenia gravis. It is also used for reversing nondepolarising neuromuscular blocking agents. Neostigmine methylsulfate may be administered by intravenous, intramuscular, or subcutaneous injection. In this research paper, a distinct stability-indicating reverse phase HPLC method was developed and validated for the quantitative determination of related impurities and degradation impurities in neostigmine methylsulfate API and injection formulation. The specific objective was to improve the resolution between European Pharmacopoeia listed impurity A and impurity B and degradation impurity of neostigmine methylsulfate API and injection formulation. The analysis was performed using Kromasil C 18 column at 30°C of column oven temperature with phosphate-buffer/acetonitrile in a gradient mode. The RP-HPLC method was developed and validated for in-house neostigmine methylsulfate synthesis process sample and injection formulation. The injection formulation sample was studied for accelerated stability, temperature cycling stability, and photostability. The validation studies for neostigmine methylsulfate synthesis process API were studied using impurity A, impurity B, and impurity C. The analytical method validation parameters studied were specificity, precision, linearity, limit of detection, limit of quantitation, accuracy, and robustness. The API and the injection formulation were subjected to forced degradation under acid, alkali, oxidation, and photolytic and thermal conditions. The proposed method showed a significantly improved RRT (Relative Retention Time) of impurity A and impurity B with a resolution greater than 1.5. The developed method eliminates the use of an ion-pairing agent and thereby a good performance of column was established.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom