Soft Tissue Dehiscence Associated with a Titanium Patient-Specific Implant: A Prosthetic Solution as an Alternative to Soft Tissue Grafting
Author(s) -
Sharaf Eldeen M. Abbas,
Mohamed Amr ElKhashab
Publication year - 2021
Publication title -
case reports in dentistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.221
H-Index - 11
eISSN - 2090-6447
pISSN - 2090-6455
DOI - 10.1155/2021/5125375
Subject(s) - medicine , soft tissue , implant , dehiscence , prosthesis , dentistry , impaction , surgery
Patients. This clinical report describes the detailed prosthodontic management of a 23-year-old male patient suffering from soft tissue complication following the placement of a 3d-printed titanium patient-specific implant. This implant was implemented simultaneously with the resection of a calcifying cystic odontogenic tumor related to the maxillary arch. Later, soft tissue dehiscence and implant exposure were encountered with subsequent food impaction, infection, and pus discharge. The treatment plan was to fabricate removable partial denture. The prosthesis was planned to be retained by bar and clip attachment on the patient-specific implant side, while on the other side, the removable prosthesis was allowed to engage two abutments with an embrasure clasp assembly in addition to covering the palatal tissues to offer protection for the soft tissue dehiscence against food impaction. Discussion. Soft tissue dehiscence and implant exposure are among the frequently reported complications associated with the patient-specific implant. The resulting infection complicates the prognosis of the implemented implant and necessitates, in some occasions, its removal. The selection of the removable prosthesis to cover soft tissue dehiscence was a conservative alternative to the implant removal as it protects the exposed titanium surface from food impaction while maintaining the implant functionality. Conclusion. Three-year follow-up showed complete resolution of the patient’s complaints while fulfilling the patient’s aesthetic and functional demands and indicates that the use of detachable overlay prosthesis could be one of the proposed treatment options.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom