z-logo
open-access-imgOpen Access
Effect of Adhesive Resin as a Modeling Liquid on Elution of Resin Composite Restorations
Author(s) -
M R Maalekipour,
Mehri Safari,
Mehrdad Barekatain,
Amirhossein Fathi
Publication year - 2021
Publication title -
international journal of dentistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.61
H-Index - 33
eISSN - 1687-8736
pISSN - 1687-8728
DOI - 10.1155/2021/3178536
Subject(s) - adhesive , composite number , elution , resin composite , materials science , composite material , dentistry , chemistry , chromatography , medicine , layer (electronics)
Background. Adhesive resin is increasingly used as a modeling liquid for composite. Based on previous studies, elution of some components from the composite mass negatively affects the oral tissues. Since few studies have focused on the effect of adhesive resin on composite mass, this study aimed to investigate the effect of dental adhesion factors as modeling liquid on the elution of substances from composite restorations. Materials and Methods. Sixty-four composite specimens (6 × 2 mm diameter × height) were prepared in four groups (n = 16) by using a Teflon ring. Composite mass was incrementally applied in four layers (0.5 mm). The control group contained no material between the layers, but other groups had one of the single bond, SE bond, and wetting resin adhesives between the layers. Specimens were immersed in distilled water and methanol. The amount of released triethylene glycol dimethacrylate (TEGDMA), urethane dimethacrylate (UDMA), and camphorquinone (CQ) was monitored by gas chromatography after 24 hours and 7 days. Data were analyzed with SPSS software through Kruskal–Wallis and Mann–Whitney U tests (α = 0.05). Results. The highest rate of released TEGDMA comonomer was seen in the wetting resin group in the water medium. The highest rate of released UDMA monomer was seen in SE bond and wetting resin groups in the methanol medium after 24 hours. The highest amount of released CQ in the methanol medium was observed in the SE bond group after 7 days. Conclusion. Single bond adhesive can be used as modeling liquid since it has no significant effect on the elution of components from composite mass. Whereas, wetting resin and SE bond adhesives are not suitable to be used as modeling liquid due to the high amounts of released TEGDMA and UDMA.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom