z-logo
open-access-imgOpen Access
Comparison of Two Analytical Platforms for CSF Biomarkers of Alzheimer’s Disease
Author(s) -
José Antonio MongeArgilés,
Carlos MuñozRuiz,
José SánchezPayá,
Ruth Gasparini Berenguer,
Maria Empar Blanco Cantó,
C. Leiva-Santana
Publication year - 2014
Publication title -
biomed research international
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.772
H-Index - 126
eISSN - 2314-6141
pISSN - 2314-6133
DOI - 10.1155/2014/765130
Subject(s) - algorithm , correlation coefficient , computer science , artificial intelligence , machine learning
Cerebrospinal fluid (CSF) biomarkers of Alzheimer's disease (AD) are currently being assessed with two different assays. Our objective was to study if there is a correlation between values obtained by both techniques, to compare their validity and search for conversion factor between values obtained for every protein. We compared the performances of two commonly used platforms, an enzyme-linked immunosorbent assay (ELISA) and a multiplex (xMAP) technology for measurement of CSF A β 1–42 , total tau (T-tau), and phosphorylated tau 181 (P-tau 181p ) proteins, in 30 AD patients and 28 control subjects. The relations between the variables of both techniques were evaluated using the Spearman p correlation coefficient ( α = 0.05). Receiver operating characteristic and area under the curve (AUC) analyses were calculated for the variables of both techniques. The two assays platforms yielded different absolute values for the various analytes, always higher in ELISA. We found some correction factor between values: 2,1- to 3-fold for A β 1–42 ; 4,1- to 4,6-fold for T-tau; and 1,4- to 1,6-fold for P-tau 181p . In addition, those values were highly correlated (A β 1–42 : r = 0.70, P < 0.01; T-tau: r = 0.90, P < 0.01; P-tau 181p : r = 0.85, P < 0.01) and the AUC for the variables showed very similar values. In conclusion, the results obtained with ELISA and xMAP platforms were highly correlated and its validity is very similar. Differences in absolute values point to the need for a clear description of the technique used. Moreover, we found some conversion factor between values of every protein that may be useful for transformation between both techniques.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom