z-logo
open-access-imgOpen Access
Lactose Malabsorption Testing in Daily Clinical Practice: A Critical Retrospective Analysis and Comparison of the Hydrogen/Methane Breath Test and Genetic Test (C/T-13910Polymorphism) Results
Author(s) -
Dietmar Enko,
Erwin Rezanka,
Robert Stolba,
Gabriele HalwachsBaumann
Publication year - 2014
Publication title -
gastroenterology research and practice
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.622
H-Index - 45
eISSN - 1687-630X
pISSN - 1687-6121
DOI - 10.1155/2014/464382
Subject(s) - malabsorption , lactose , breath test , gastroenterology , medicine , genotype , hydrogen breath test , ingestion , lactose intolerance , small intestinal bacterial overgrowth , biochemistry , chemistry , gene , irritable bowel syndrome , helicobacter pylori
The aim of this study was to establish a retrospective evaluation and comparison of the hydrogen/methane (H 2 /CH 4 ) breath test and genetic test (C/T −13910 polymorphism) results in lactose malabsorption testing. In total 263 consecutive patients with suspected lactose malabsorption were included in this study. They underwent the H 2 /CH 4 breath test following the ingestion of 50 g lactose and were tested for the C/T −13910 polymorphism. In total 51 patients (19.4%) had a C/C −13910 genotype, indicating primary lactose malabsorption. Only 19 patients (7.2%) also had a positive H 2 /CH 4 breath test. All in all 136 patients (51.69%) had a C/T −13910 and 76 patients (28.91%) a T/T −13910 genotype, indicating lactase persistence. Four patients (1.5%) with the C/T −13910 genotype and one patient (0.4%) with the T/T −13910 genotype had a positive H 2 /CH 4 breath test result, indicating secondary lactose malabsorption. Cohen's Kappa measuring agreement between the two methods was 0.44. Twenty patients (7.6%) with a positive H 2 /CH 4 peak within 60 minutes after lactose ingestion were classified as patients with lactose-dependent small intestinal bacterial overgrowth (SIBO). In conclusion, only moderate agreement between the breath test and the genetic test was shown. Secondary lactose malabsorption as well as preanalytical limitations of the combined H 2 /CH 4 breath test procedure can cause discrepant results. This trial is registered with K-42-13.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom