z-logo
open-access-imgOpen Access
Trilogy-Constrained Acetabular Component for Recurrent Dislocation
Author(s) -
Annette Vest Andersen,
Anne Grete Kjersgaard,
Søren Solgaard
Publication year - 2013
Publication title -
isrn orthopedics
Language(s) - English
Resource type - Journals
eISSN - 2090-617X
pISSN - 2090-6161
DOI - 10.1155/2013/629201
Subject(s) - trilogy , component (thermodynamics) , dislocation , medicine , computer science , materials science , artificial intelligence , physics , composite material , thermodynamics
32 patients received a Trilogy- or Trilogy-Longevity-constrained acetabular liner for recurrent dislocations after total hip replacement. The constrained liner was inserted into a well-fixed Trilogy acetabular shell with snap fit. At 1.8-year followup (range 3–63 months), 4 patients had suffered further dislocation(s) (12%), and one patient had revision surgery for a loosened acetabular shell. Radiologic evaluation detected no definitively loose components, but one patient with progressing radiolucent lines around the femoral component and one patient with an acetabular cyst were found, as well as a patient with a loose locking ring (but otherwise no failure). The nineteen patients who were available for the present followup had a mean Harris Hip Score of 81. The constrained liner is an effective method of dealing with recurrent dislocations in well-fixed components.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom