z-logo
open-access-imgOpen Access
Encrusted Ureteral Stent Retrieval Using Flexible Ureteroscopy with a Ho: YAG Laser
Author(s) -
Takashi Kawahara,
Hiroki Ito,
Hideyuki Terao,
Takehiko Ogawa,
Hiroji Uemura,
Yoshinobu Kubota,
Junichi Matsuzaki
Publication year - 2012
Publication title -
case reports in medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.2
H-Index - 20
eISSN - 1687-9627
pISSN - 1687-9635
DOI - 10.1155/2012/862539
Subject(s) - medicine , ureteroscopy , ureter , stent , hydronephrosis , surgery , urology , urinary system
A 23-year-old female had bilateral ureteral stents placed due to bilateral renal stones and hydronephrosis. The bilateral ureteral stents were changed every 3 months. A kidney ureter bladder (KUB) film showed left encrustation along the ureteral stent thus necessitating removal; however, the ureteral stent could not be removed cystoscopically. The ureteral stent was, therefore, extracted using flexible ureteroscopy (URS) with a holmium (Ho): yttrium aluminum garnet (YAG) laser.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom