Physicochemical Characterization andIn VivoEvaluation of Amorphous and Partially Crystalline Calcium Phosphate Coatings Fabricated on Ti-6Al-4V Implants by the Plasma Spray Method
Author(s) -
Estevam A. Bonfante,
Lukasz Witek,
Nick Tovar,
Marcelo Suzuki,
Charles Marin,
Daniel Granato,
Paulo G. Coelho
Publication year - 2012
Publication title -
international journal of biomaterials
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.576
H-Index - 28
eISSN - 1687-8795
pISSN - 1687-8787
DOI - 10.1155/2012/603826
Subject(s) - amorphous calcium phosphate , bioceramic , implant , scanning electron microscope , materials science , calcium , fourier transform infrared spectroscopy , in vivo , chemistry , biomedical engineering , dentistry , composite material , chemical engineering , metallurgy , surgery , medicine , engineering , microbiology and biotechnology , biology
Objective . To characterize the topographic and chemical properties of 2 bioceramic coated plateau root form implant surfaces and evaluate their histomorphometric differences at 6 and 12 weeks in vivo . Methods . Plasma sprayed hydroxyapatite (PSHA) and amorphous calcium phosphate (ACP) surfaces were characterized by scanning electron microscopy (SEM), interferometry (IFM), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FT-IR). Implants were placed in the radius epiphysis, and the right limb of dogs provided implants that remained for 6 weeks, and the left limb provided implants that remained 12 weeks in vivo . Thin sections were prepared for bone-to-implant contact (BIC) and bone-area-fraction occupancy (BAFO) measurements (evaluated by Friedman analysis P < 0.05). Results . Significantly, higher S a ( P < 0.03) and S q ( P < 0.02) were observed for ACP relative to PSHA. Chemical analysis revealed significantly higher HA, calcium phosphate, and calcium pyrophosphate for the PSHA surface. BIC and BAFO measurements showed no differences between surfaces. Lamellar bone formation in close contact with implant surfaces and within the healing chambers was observed for both groups. Conclusion . Given topographical and chemical differences between PSHA and ACP surfaces, bone morphology and histomorphometric evaluated parameters showed that both surfaces were osseoconductive in plateau root form implants.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom