Bent Intramedullary Femoral Nail: Surgical Technique of Removal and Reconstruction
Author(s) -
Vasileios I. Sakellariou,
Stamatis Kyriakopoulos,
Helias Kotoulas,
Ioannis Sofianos
Publication year - 2011
Publication title -
case reports in orthopedics
Language(s) - English
Resource type - Journals
eISSN - 2090-6749
pISSN - 2090-6757
DOI - 10.1155/2011/614509
Subject(s) - intramedullary rod , medicine , osteotomy , fixation (population genetics) , surgery , femur , nail (fastener) , range of motion , bent molecular geometry , population , chemistry , materials science , environmental health , organic chemistry , metallurgy
A secondary high-velocity trauma to a previously stabilized femoral fracture with intramedullary nailing is rare. In this paper, we present the management of a 40-year-old man presented with a bent intramedullary nail due to secondary trauma. A lateral longitudinal femoral osteotomy was used for the resection of the distorted nail. The femur was reconstructed with a new nail, and the fixation of the osteotomy was achieved with plate and cerclage wires. Five months postrevision surgery, callus formation was evident and the patient regained a normal range of motion and gait, walking with a single cane.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom