z-logo
open-access-imgOpen Access
Optimizing the Raman signal for characterizing organic samples: The effect of slit aperture and exposure time
Author(s) -
João Carlos Lázaro,
Marcos Tadeu Tavares Pacheco,
Kátia Calligaris Rodrigues,
Carlos José de Lima,
Leonardo Marmo Moreira,
Antônio Balbin Villaverde,
Landulfo Silveira
Publication year - 2009
Publication title -
spectroscopy an international journal
Language(s) - English
Resource type - Journals
eISSN - 1875-922X
pISSN - 0712-4813
DOI - 10.1155/2009/764524
Subject(s) - raman spectroscopy , spectrometer , optics , aperture (computer memory) , slit , signal (programming language) , spectral resolution , wavelength , time delay and integration , spectrograph , resolution (logic) , spectral line , materials science , analytical chemistry (journal) , chemistry , physics , chromatography , astronomy , artificial intelligence , computer science , acoustics , programming language
The present work is focused on the influence of the slit aperture and time exposure of the infrared light on the Charge Coupled Device (CCD) in relation to their physical effects, in order to improve the Raman spectrum characteristics. Indeed, the alterations in slit aperture and CCD time exposure affect significantly important spectral properties, such as the spectral intensity, Signal to Noise Ratio (SNR) and band width resolution of the Raman spectra. Therefore, the present proposal has the aim of to found the optimum conditions of instrumental arrangement, involving the minimum collection time and maximum signal quality in dispersive Raman spectrometers. Samples of dehydrated human teeth and naphthalene were evaluated with a Raman dispersive spectrometer employing excitation wavelength of 830 nm in several integration times and spectrometer slit apertures. The analysis of the spectral intensity, SNR and band width of selected Raman peaks allowed to infer that these properties of a dispersive Raman spectrum depend directly of the exposure time on the detector as well as spectrograph slit aperture. It is important to register that the higher SNR was obtained with higher exposure time intervals. To the samples evaluated in the present article, the band width has lower values for slit apertures of 100–150 μm, i.e., in this aperture range the spectral resolution is maximum. On the publisher-id hand, the intensity and SNR of the Raman spectra becomes optimal for slit apertures of 150–200 μm, since this aperture does not affect significantly the integrity of the Raman signal. In this way, we can to propose that in approximately 150 μm, it is possible to obtain an optimum condition, involving spectral resolution as well as SNR and spectral intensity. In any case, depending of the priorities of each spectral measurement, the instrumental conditions can be altered according with the necessities of each specific chemical analysis involving a determined sample. The present data are discussed in details in agreement with recent data from literature.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom