Hypoxic pulmonary vasoconstriction does not contribute to pulmonary blood flow heterogeneity in normoxia in normal supine humans
Author(s) -
Tatsuya Arai,
A. Cortney Henderson,
David J. Dubowitz,
David L. Levin,
P J Friedman,
Richard B. Buxton,
G. Kim Prisk,
Susan R. Hopkins
Publication year - 2008
Publication title -
journal of applied physiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.253
H-Index - 229
eISSN - 8750-7587
pISSN - 1522-1601
DOI - 10.1152/japplphysiol.90759.2008
Subject(s) - hypoxic pulmonary vasoconstriction , hyperoxia , perfusion , hypoxia (environmental) , supine position , lung , blood flow , chemistry , oxygenation , arterial blood , medicine , cardiology , anesthesia , oxygen , organic chemistry
We hypothesized that some of the heterogeneity of pulmonary blood flow present in the normal human lung in normoxia is due to hypoxic pulmonary vasoconstriction (HPV). If so, mild hyperoxia would decrease the heterogeneity of pulmonary perfusion, whereas it would be increased by mild hypoxia. To test this, six healthy nonsmoking subjects underwent magnetic resonance imaging (MRI) during 20 min of breathing different oxygen concentrations through a face mask [normoxia, inspired O(2) fraction (Fi(O(2))) = 0.21; hypoxia, Fi(O(2)) = 0.125; hyperoxia, Fi(O(2)) = 0.30] in balanced order. Data were acquired on a 1.5-T MRI scanner during a breath hold at functional residual capacity from both coronal and sagittal slices in the right lung. Arterial spin labeling was used to quantify the spatial distribution of pulmonary blood flow in milliliters per minute per cubic centimeter and fast low-angle shot to quantify the regional proton density, allowing perfusion to be expressed as density-normalized perfusion in milliliters per minute per gram. Neither mean proton density [hypoxia, 0.46(0.18) g water/cm(3); normoxia, 0.47(0.18) g water/cm(3); hyperoxia, 0.48(0.17) g water/cm(3); P = 0.28] nor mean density-normalized perfusion [hypoxia, 4.89(2.13) ml x min(-1) x g(-1); normoxia, 4.94(1.88) ml x min(-1) x g(-1); hyperoxia, 5.32(1.83) ml x min(-1) x g(-1); P = 0.72] were significantly different between conditions in either imaging plane. Similarly, perfusion heterogeneity as measured by relative dispersion [hypoxia, 0.74(0.16); normoxia, 0.74(0.10); hyperoxia, 0.76(0.18); P = 0.97], fractal dimension [hypoxia, 1.21(0.04); normoxia, 1.19(0.03); hyperoxia, 1.20(0.04); P = 0.07], log normal shape parameter [hypoxia, 0.62(0.11); normoxia, 0.72(0.11); hyperoxia, 0.70(0.13); P = 0.07], and geometric standard deviation [hypoxia, 1.88(0.20); normoxia, 2.07(0.24); hyperoxia, 2.02(0.28); P = 0.11] was also not different. We conclude that HPV does not affect pulmonary perfusion heterogeneity in normoxia in the normal supine human lung.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom