Force-velocity test on a stationary cycle ergometer: methodological recommendations
Author(s) -
Briar L. Rudsits,
Will G. Hopkins,
Christophe Hautier,
David M. Rouffet
Publication year - 2017
Publication title -
journal of applied physiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.253
H-Index - 229
eISSN - 8750-7587
pISSN - 1522-1601
DOI - 10.1152/japplphysiol.00719.2017
Subject(s) - cadence , mathematics , crank , dynamometer , cycle ergometer , power (physics) , torque , polynomial and rational function modeling , polynomial , physical medicine and rehabilitation , medicine , physics , mathematical analysis , geometry , engineering , heart rate , quantum mechanics , cylinder , blood pressure , thermodynamics , aerospace engineering
Force-velocity tests performed on stationary cycle ergometers are widely used to assess the torque- and power-generating capacities of the lower limbs. The aim of this study was to identify how testing and modeling procedures influence the assessment of individual torque-cadence and power-cadence relationships. Seventeen males completed 62 ± 16 pedal cycles from six 6-s all-out efforts interspersed with 5 min of rest. True measures of maximal power for a particular cadence were obtained for 24 ± 3 pedal cycles, while power was only 94 ± 3% of the true maximum in 19 ± 5 pedal cycles. Pedal cycles showing maximal levels of power also displayed higher levels of electromyography (EMG: 89 ± 7 vs . 87 ± 7%) and coactivation (34 ± 11 vs . 31 ± 10 arbitrary units), as well as lower variability in crank torque and EMG profiles. Compared with the linear and second-order polynomial models that are traditionally used, a better goodness of fit was obtained when the torque-cadence and power-cadence relationships were predicted using second- and third-order polynomials, respectively. The later modeling procedures also revealed an asymmetry in the power-cadence relationship in most participants (i.e., 15 out of 17) and provided a better estimation of maximal cadence [C max : 214 ± 20 revolutions/min (rpm)] from the x-intercept of power-cadence relationships (C 0 : 214 ± 14 rpm). Therefore, we recommend predicting the individual shapes of torque- and power-cadence relationships using second- and third-order polynomial regressions after having selected pedal cycles during which true measures of cadence-specific maximal power were recorded. NEW & NOTEWORTHY This study is the first to demonstrate that suboptimal activation of the lower limb muscles accompanied reductions in cadence-specific levels of torque and power produced during a force-velocity test performed on a stationary cycle ergometer. This research is also the first to show that, in most noncyclist participants, torque-cadence relationships are not linear, whereas power-cadence relationships display asymmetric shapes, with power production decreasing rapidly when cadence increases beyond 180 revolutions/min.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom