Systolic-diastolic functional coupling in healthy children and in those with dilated cardiomyopathy
Author(s) -
Mark K. Friedberg,
Renée Margossian,
Minmin Lü,
Laura MercerRosa,
Heather Henderson,
Arni Nutting,
Kevin G. Friedman,
Kimberly Molina,
Karen Altmann,
Charles E. Canter,
Lynn A. Sleeper,
Steven D. Colan
Publication year - 2016
Publication title -
journal of applied physiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.253
H-Index - 229
eISSN - 8750-7587
pISSN - 1522-1601
DOI - 10.1152/japplphysiol.00635.2015
Subject(s) - cardiology , medicine , dilated cardiomyopathy , diastole , ejection fraction , diastolic function , heart failure , blood pressure
Systolic and diastolic function affect dilated cardiomyopathy (DCM) outcomes. However, systolic-diastolic coupling, as a distinct characteristic, may itself affect function but is poorly characterized. We hypothesized that echocardiographic left ventricular (LV) longitudinal systolic tissue velocities (S') correlate with diastolic longitudinal velocities (E') and that their relationship is associated with ventricular function and that this relationship is impaired in pediatric DCM. We analyzed data from the Pediatric Heart Network Ventricular Volume Variability study, using linear regression and generalized additive modeling to assess relationships between S' and E' at the lateral and septal mitral annulus. We explored relationships between the systolic:diastolic (S:D) coupling ratio (S':E' relative to age) and ventricular function. Up to 4 echocardiograms from 130 DCM patients (mean age: 9.3 ± 6.1 yr) and 1 echocardiogram from each of 591 healthy controls were analyzed. S' and E' were linearly related in controls (r = 0.64, P < 0.001) and DCM (r = 0.83, P < 0.001). In DCM, the magnitude of association between S' and E' was reduced with progressive ventricular remodeling. The S:D ratio was more strongly associated with LV function in controls vs. DCM. The septal S:D ratio was higher (presumed worse) in DCM vs. controls (0.69 ± 0.13 vs. 0.62 ± 0.12, P = 0.001). A higher septal S:D ratio was associated with worse LV dimensions (parameter estimate: 0.0061, P = 0.004), mass (parameter estimate: 0.0074, P = 0.002), ejection fraction (parameter estimate: -0.0303, P = 0.024), and inflow propagation (parameter estimate: -0.3538, P < .001). S:D coupling becomes weaker in DCM with LV remodeling and dysfunction. The S:D coupling ratio may be useful to assess coupling, warranting study in relation to patient outcomes.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom