Acute hypoxia impairs dynamic cerebral autoregulation: results from two independent techniques
Author(s) -
Andrew W. Subudhi,
Ronney B. Panerai,
Robert C. Roach
Publication year - 2009
Publication title -
journal of applied physiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.253
H-Index - 229
eISSN - 8750-7587
pISSN - 1522-1601
DOI - 10.1152/japplphysiol.00498.2009
Subject(s) - cerebral autoregulation , cuff , medicine , cerebral blood flow , supine position , anesthesia , middle cerebral artery , autoregulation , blood pressure , cardiology , hypoxia (environmental) , transcranial doppler , surgery , ischemia , chemistry , oxygen , organic chemistry
We investigated the effect of acute hypoxia (AH) on dynamic cerebral autoregulation (CA) using two independent assessment techniques to clarify previous, conflicting reports. Twelve healthy volunteers (6 men, 6 women) performed six classic leg cuff tests, three breathing normoxic (Fi(O2) = 0.21) and three breathing hypoxic (Fi(O2) = 0.12) gas, using a single blinded, Latin squares design with 5-min washout between trials. Continuous measurements of middle cerebral artery blood flow velocity (CBFv; DWL MultiDop X2) and radial artery blood pressure (ABP; Colin 7000) were recorded in the supine position during a single experimental session. Autoregulation index (ARI) scores were calculated using the model of Tiecks et al. (Tiecks FP, Lam AM, Aaslid R, Newell DW. Stroke 26: 1014-1019, 1995) from ABP and CBFv changes following rapid cuff deflation (cuff ARI) and from ABP to CBFv transfer function, impulse, and step responses (TFA ARI) obtained during a 4-min period prior to cuff inflation. A new measure of %CBFv recovery 4 s after peak impulse was also derived from TFA. AH reduced cuff ARI (5.65 +/- 0.70 to 5.01 +/- 0.96, P = 0.04), TFA ARI (4.37 +/- 0.76 to 3.73 +/- 0.71, P = 0.04), and %Recovery (62.2 +/- 10.9% to 50.8 +/- 9.9%, P = 0.03). Slight differences between TFA and cuff ARI values may be attributed to heightened sympathetic activity during cuff tests as well as differential sensitivity to low- and high-frequency components of CA. Together, results provide consistent evidence that CA is impaired with AH. In addition, these findings demonstrate the potential utility of TFA ARI and %Recovery scores for future CA investigations.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom