z-logo
open-access-imgOpen Access
The effect of increased genioglossus activity and end-expiratory lung volume on pharyngeal collapse
Author(s) -
Amy S. Jordan,
David P. White,
Robert L. Owens,
Danny J. Eckert,
Shilpa Rahangdale,
Susie YimYeh,
Atul Malhotra
Publication year - 2010
Publication title -
journal of applied physiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.253
H-Index - 229
eISSN - 8750-7587
pISSN - 1522-1601
DOI - 10.1152/japplphysiol.00373.2010
Subject(s) - genioglossus , medicine , anesthesia , lung volumes , supine position , continuous positive airway pressure , airway , critical closing pressure , positive end expiratory pressure , obstructive sleep apnea , cardiology , lung , mechanical ventilation , hemodynamics
Increasing either genioglossus muscle activity (GG) or end-expiratory lung volume (EELV) improves airway patency but not sufficiently for adequate treatment of obstructive sleep apnea (OSA) in most patients. The mechanisms by which these variables alter airway collapsibility likely differ, with increased GG causing airway dilation, whereas increased EELV may stiffen the airway walls through caudal traction. We sought to determine whether the airway stabilizing effect of GG activation is enhanced when EELV is increased. To investigate this aim, 15 continuous positive airway pressure (CPAP)-treated OSA patients were instrumented with an epiglottic catheter, intramuscular GG-EMG electrodes, magnetometers, and a nasal mask/pneumotachograph. Subjects slept supine in a sealed, head-out plastic chamber in which the extra-thoracic pressure could be lowered (to raise EELV) while on nasal CPAP with a variable deadspace to allow CO(2) stimulation (and GG activation). The pharyngeal critical closing pressure (P(CRIT)) was measured by sudden reduction of CPAP for three to five breaths each minute during non-rapid eye movement (NREM) sleep in 4 conditions: a) baseline, b) 500 ml increased EELV, c) 50% increased GG, and d) conditions b and c combined. P(CRIT) was found to be reduced from 2.2 + or - 0.7 cmH(2)O at baseline to -1.0 + or - 0.5 with increased EELV, 0.6 + or - 0.7 with increased GG and -1.6 + or - 0.7 when both variables were raised (P < 0.001). The slope of the P(CRIT) curves remained unchanged in all conditions (P = 0.05). However, the CPAP level at which flow limitation developed was lower in both increased EELV conditions (P = 0.001). These findings indicate that while both increased GG and EELV improve airway collapsibility, the combination of both variables has little additional effect over increasing EELV alone.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom