z-logo
open-access-imgOpen Access
Measurements of pulmonary gas exchange efficiency using expired gas and oximetry: results in normal subjects
Author(s) -
John B. West,
Daniel L. Wang,
G. Kim Prisk
Publication year - 2018
Publication title -
ajp lung cellular and molecular physiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.892
H-Index - 163
eISSN - 1522-1504
pISSN - 1040-0605
DOI - 10.1152/ajplung.00499.2017
Subject(s) - oxygen–haemoglobin dissociation curve , arterial blood , oxygen , hypoxemia , medicine , arterial blood gas analysis , anesthesia , pulse oximetry , bohr effect , expired air , carbon dioxide , cardiology , room air distribution , chemistry , hemoglobin , thermodynamics , organic chemistry , physics
We are developing a novel, noninvasive method for measuring the efficiency of pulmonary gas exchange in patients with lung disease. The patient wears an oximeter, and we measure the partial pressures of oxygen and carbon dioxide in inspired and expired gas using miniature analyzers. The arterial Po 2 is then calculated from the oximeter reading and the oxygen dissociation curve, using the end-tidal Pco 2 to allow for the Bohr effect. This calculation is only accurate when the oxygen saturation is <94%, and therefore, these normal subjects breathed 12.5% oxygen. When the procedure is used in patients with hypoxemia, they breathe air. The Po 2 difference between the end-tidal and arterial values is called the “oxygen deficit.” Preliminary data show that this index increases substantially in patients with lung disease. Here we report measurements of the oxygen deficit in 20 young normal subjects (age 19 to 31 yr) and 11 older normal subjects (47 to 88 yr). The mean value of the oxygen deficit in the young subjects was 2.02 ± 3.56 mmHg (means ± SD). This mean is remarkably small. The corresponding value in the older group was 7.53 ± 5.16 mmHg (means ± SD). The results are consistent with the age-related trend of the traditional alveolar-arterial difference, which is calculated from the calculated ideal alveolar Po 2 minus the measured arterial Po 2 . That measurement requires an arterial blood sample. The present study suggests that this noninvasive procedure will be valuable in assessing the degree of impaired gas exchange in patients with lung disease.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom