z-logo
open-access-imgOpen Access
Length-tension relationship of the external anal sphincter muscle: implications for the anal canal function
Author(s) -
Mahadevan Rajasekaran,
Yanfen Jiang,
Valmik Bhargava,
Ryan Littlefield,
Andrew Lee,
Richard L. Lieber,
Ravinder K. Mittal
Publication year - 2008
Publication title -
ajp gastrointestinal and liver physiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.644
H-Index - 169
eISSN - 1522-1547
pISSN - 0193-1857
DOI - 10.1152/ajpgi.00033.2008
Subject(s) - sarcomere , isometric exercise , anatomy , tension (geology) , in vivo , anal canal , biomedical engineering , protein filament , materials science , chemistry , myocyte , biology , compression (physics) , medicine , surgery , composite material , microbiology and biotechnology , rectum
The length at which a muscle operates in vivo (operational length) and the length at which it generates maximal force (optimal length) may be quite different. We studied active and passive length-tension characteristics of external anal sphincter (EAS) in vivo and in vitro to determine the optimal and operational length of rabbit EAS. For the in vitro studies, rings of EAS (n = 4) were prepared and studied in a muscle bath under isometric conditions. For in vivo studies, female rabbits (n = 19) were anesthetized and anal canal pressure was recorded by use of a sleeve sensor placed in the custom-designed catheter holders of 4.5-, 6-, and 9-mm diameters. Measurements were obtained at rest and during EAS electrical stimulation. Sarcomere length of EAS muscle was measured by laser diffraction technique with no probe and three probes in the anal canal. In vitro studies revealed 2,054 mN/cm(2) active tension at optimal length. In vivo studies revealed a probe size-dependent increase in anal canal pressure and tension. Maximal increase in anal canal tension with stimulation was recorded with the 9-mm probe. Increases in anal canal tension with increase in probe size were completely abolished by pancuronium bromide. EAS muscle sarcomere length without and with 9-mm probe in the anal canal were 2.11 +/- 0.08 and 2.99 +/- 0.07 microm, respectively. Optimal sarcomere length, based on the thin filament length measured by thin filament analysis, is 2.44 +/- 0.10 microm. These data show that the operational length of EAS is significantly shorter than its optimal length. Our findings provide insight into EAS function and we propose the possibility of increasing anal canal pressure by surgical manipulation of the EAS sarcomere length.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom