Reducing Functional MR Imaging Acquisition Times by Optimizing Workflow
Author(s) -
Wilson B. Chwang,
Michael Iv,
Jason Smith,
Aleksandrs Kalnins,
Jake Mickelsen,
Roland Bammer,
Dominik Fleischmann,
David B. Larson,
Max Wintermark,
Michael Zeineh
Publication year - 2017
Publication title -
radiographics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.866
H-Index - 172
eISSN - 1527-1323
pISSN - 0271-5333
DOI - 10.1148/rg.2017160035
Subject(s) - medicine , workflow , functional imaging , magnetic resonance imaging , medical physics , image quality , radiology , artificial intelligence , computer science , database , image (mathematics)
Functional magnetic resonance (MR) imaging is a complex, specialized examination that is able to noninvasively measure information critical to patient care such as hemispheric language lateralization ( 1 ). Diagnostic functional MR imaging requires extensive patient interaction as well as the coordinated efforts of the entire health care team. We observed in our practice at an academic center that the times to perform functional MR imaging examinations were excessively lengthy, making scheduling of the examination difficult. The purpose of our project was to reduce functional MR imaging acquisition times by increasing the efficiency of our workflow, using specific quality tools to drive improvement of functional MR imaging. We assembled a multidisciplinary team and retrospectively reviewed all functional MR imaging examinations performed at our institution from January 2013 to August 2015. We identified five key drivers: (a) streamlined protocols, (b) consistent patient monitoring, (c) clear visual slides and audio, (d) improved patient understanding, and (e) minimized patient motion. We then implemented four specific interventions over a period of 10 months: (a) eliminating intravenous contrast medium, (b) reducing repeated language paradigms, (c) updating technologist and physician checklists, and (d) updating visual slides and audio. Our mean functional MR imaging acquisition time was reduced from 76.3 to 53.2 minutes, while our functional MR imaging examinations remained of diagnostic quality. As a result, we reduced our routine scheduling time for functional MR imaging from 2 hours to 1 hour, improving patient comfort and satisfaction as well as saving time for additional potential MR imaging acquisitions. Our efforts to optimize functional MR imaging workflow constitute a practice quality improvement project that is beneficial for patient care and can be applied broadly to other functional MR imaging practices. © RSNA, 2017.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom