99mTc-MAG3: Image Wisely
Author(s) -
Andrew Taylor,
Russell D. Folks,
Fazlur Rahman,
Aruna Polsani,
Eva V. Dubovsky,
Raghuveer Halkar,
Amita K. Manatunga
Publication year - 2017
Publication title -
radiology
Language(s) - Uncategorized
Resource type - Journals
SCImago Journal Rank - 3.118
H-Index - 295
eISSN - 1527-1315
pISSN - 0033-8419
DOI - 10.1148/radiol.2017152311
Subject(s) - medicine , nuclear medicine , radioisotope renography , renal function
Purpose To determine if commonly administered doses of technetium 99m ( 99m Tc) mertiatide (MAG 3 ) in the range of 300-370 MBq (approximately 8-10 mCi) contribute to image interpretation and justify the resulting radiation exposure. Materials and Methods The respective institutional review boards approved this HIPAA-compliant study and waived informed consent. Baseline and furosemide 99m Tc-MAG 3 imaging examinations in 50 patients suspected of having renal obstruction and 48 patients suspected of having renovascular hypertension (RVH) were randomly selected from archived databases and were independently scored by three experienced readers without access to 2-second flow images. Readers were blinded to their original scores, and then they rescored each examination with access to high-activity 2-second flow images. Relative renal function was determined after a low activity (62.9 MBq ± 40.7) baseline acquisition for RVH and a high activity (303.4 MBq ± 48.1) acquisition after administration of enalaprilat. Data were analyzed by using random effects analysis of variance and mean and standard error of the mean for the difference between sets of scores and the difference between relative function measurements. Results There was no significant difference in the scores without flow images compared with blinded scores with high-activity flow images for patients suspected of having obstruction (P = .80) or RVH (P = .24). Moreover, there was no significant difference in the relative uptake measurements after administration of low and high activities (P > .99). Conclusion Administered doses of 99m Tc-MAG 3 in the range of 300-370 MBq (approximately 8-10 mCi) do not affect the relative function measurements or contribute to interpretation of images in patients suspected of having RVH or obstruction compared with administration of lower doses; unnecessary radiation exposure can be avoided by administering doses in the range of 37-185 MBq as recommended incurrent guidelines. © RSNA, 2017.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom