Use of the VITEK 2 System for Rapid Identification of Clinical Isolates of Staphylococci from Bloodstream Infections
Author(s) -
Teresa Spanu,
Maurizio Sanguinetti,
Daniela Ciccaglione,
Tiziana D’Inzeo,
Lucio Romano,
Fiammetta Leone,
Giovanni Fadda
Publication year - 2003
Publication title -
journal of clinical microbiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.349
H-Index - 255
eISSN - 1070-633X
pISSN - 0095-1137
DOI - 10.1128/jcm.41.9.4259-4263.2003
Subject(s) - microbiology and biotechnology , coagulase , staphylococcus epidermidis , micrococcaceae , typing , staphylococcus , biology , staphylococcus aureus , phage typing , staphylococcal infections , bacteremia , antibacterial agent , bacteria , antibiotics , genetics
Staphylococci are an increasing cause of bloodstream infections. Rapid reliable identification of these organisms is essential for accurate diagnosis and prompt effective treatment. We evaluated the ability of the VITEK 2 system (bioMérieux, Inc, Hazelwood, Mo.) to identify these organisms rapidly and accurately. A total of 405 clinically relevant nonduplicate staphylococcal isolates (Staphylococcus aureus, n = 130; coagulase-negative staphylococci, n = 275) collected from blood cultures were tested. VITEK 2 results were considered correct when they were identical to those furnished by the comparison method based on the ID 32 STAPH system (bioMérieux, Marcy l'Etoile, France) plus supplementary manual testing. When discrepancies occurred, isolate identity was verified by molecular typing. The VITEK 2 correctly identified 387 (95.6%) isolates at the species level: 379 (including all but one [99.2%] of 130 S. aureus isolates and 249 of 275 [90.5%] coagulase-negative isolates) were identified by the automated reading; for the other eight, supplemental tests suggested by the manufacturer had to be used. Only one strain (0.2%) was misidentified (Staphylococcus hominis as Staphylococcus epidermidis), and four (1%), all S. epidermidis, were not identified. For the remaining 13 strains (including 10 S. hominis), the VITEK 2 system was unable to discriminate among two species, and no supplemental tests were suggested for conclusive identification. Over 90% of results were obtained within 4 h. These results suggest that the VITEK 2 system can provide rapid, accurate, and reliable species-level identification of staphylococci responsible for bloodstream infections, although there is room for improvement in the identification of certain coagulase-negative species, especially S. hominis.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here