z-logo
open-access-imgOpen Access
Evaluation of a New Combined Antigen and Antibody Human Immunodeficiency Virus Screening Assay, VIDAS HIV DUO Ultra
Author(s) -
Bernard Weber,
Annemarie Berger,
Holger F. Rabenau,
Hans Wilhelm Doerr
Publication year - 2002
Publication title -
journal of clinical microbiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.349
H-Index - 255
eISSN - 1070-633X
pISSN - 0095-1137
DOI - 10.1128/jcm.40.4.1420-1426.2002
Subject(s) - seroconversion , virology , antigen , antibody , medicine , window period , human immunodeficiency virus (hiv) , virus , immunology , serology
Combined antigen and antibody screening (fourth-generation) assays reduce the diagnostic window period between the time of human immunodeficiency virus (HIV) infection and laboratory diagnosis by 4 days, on average, in comparison to antibody-only (third generation) enzyme immunoassays (EIAs). The aim of the present study was to assess whether the new VIDAS HIV DUO Ultra (Biomérieux, Marcy-l'Etoile, France) showed an improved sensitivity and specificity in comparison to licensed fourth-generation assays. A total of 16 seroconversion panels, 15 cell culture supernatants infected with different HIV type 1 (HIV-1) subtypes, and 257 potentially cross-reactive serum samples were tested with VIDAS DUO HIV Ultra, Genscreen Plus HIV Ag-Ab, Enzygnost HIV Integral, Enzymun-Test HIV Combi, Genscreen HIV 1/2, version 2 (third-generation EIA), and Genetic Systems HIV-1 Ag EIA (p24 antigen assay). VIDAS HIV DUO Ultra showed a comparable sensitivity to the single p24 antigen assay in seroconversion panels and a dilution series of virus lysates. The diagnostic window was reduced with VIDAS HIV DUO Ultra by 3.82 days, on average, in comparison with the fourth-generation assay with the lowest sensitivity of the antigen detection module. HIV-1 infection was detected 5.88 days earlier than with third-generation EIA. The mean time delay between reverse transcription-PCR and VIDAS HIV DUO Ultra was only 2.31 days. The specificity of fourth-generation assays after retesting ranged between 98.1 and 100%. In conclusion, VIDAS HIV DUO Ultra can replace single-antigen screening for laboratory diagnosis and screening of HIV infection in blood donors. There was no evidence for a second diagnostic window due to impaired sensitivity of the antibody detection module of all the fourth-generation EIAs evaluated in the present study. The specificity after initial and/or repeated testing of VIDAS HIV DUO Ultra was equivalent to that of a third-generation assay.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here