New Automated Chemiluminescence Immunoassay for Simultaneous but Separate Detection of Human Immunodeficiency Virus Antigens and Antibodies
Author(s) -
Roberto Alonso,
Paula López-Roa,
Marisol Suárez,
Emilio Bouza
Publication year - 2014
Publication title -
journal of clinical microbiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.349
H-Index - 255
eISSN - 1070-633X
pISSN - 0095-1137
DOI - 10.1128/jcm.03486-13
Subject(s) - immunoassay , human immunodeficiency virus (hiv) , chemiluminescent immunoassay , antibody , chemiluminescence , antigen , medicine , hiv screening , prospective cohort study , virology , sida , immunology , viral disease , chemistry , chromatography , men who have sex with men , syphilis
The recently launched Liaison XL Murex HIV Ab/Ag assay (DiaSorin S.p.A) uses chemiluminescence immunoassay technology for the combined qualitative determination of p24 antigen of HIV-1 and specific antibodies to both HIV-1 and HIV-2. We studied 571 serum samples from those submitted to our laboratory for HIV screening. The samples were divided into 3 subsets: subset A, 365 samples collected prospectively during 1 week; subset B, 158 samples from confirmed HIV-positive patients; and subset C, 48 samples with a positive screening result but a negative or indeterminate confirmatory test result. Our standard screening/confirmatory algorithm was used as a reference. In subset A (prospective), 5 samples were positive and 360 negative by the standard procedure. Liaison XL Murex HIV Ab/Ag correctly identified all 5 positive samples (100%) and 357 negative samples (99.2%). In subset B (confirmed positive), all 158 positive samples were in total agreement in both procedures. In subset C (screen positive only), Liaison XL Murex HIV Ab/Ag yielded accurate results in 42 out of 48 samples (87.5%). Global sensitivity and specificity for Liaison XL Murex HIV Ab/Ag (all subsets included) were 98.3% and 98.5%, respectively. Considering only nonselected prospective samples and confirmed positive samples (subsets A and B), the corresponding sensitivity and specificity values were 100% and 99.2%, respectively. The new fully automated HIV screening test showed high sensitivity and specificity compared to our standard algorithm. Its added advantage of being able to detect HIV-1 and HIV-2 antibodies and p24 antigen separately could prove useful in the diagnosis of early infections.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom