Stability Studies on Dry Swabs and Wet Mailed Swabs for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Aptima Assays
Author(s) -
Jeanne Moncada,
Carey Clark,
Jeffrey P. Holden,
Edward W. Hook,
Charlotte A. Gaydos,
Julius Schachter
Publication year - 2017
Publication title -
journal of clinical microbiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.349
H-Index - 255
eISSN - 1070-633X
pISSN - 0095-1137
DOI - 10.1128/jcm.02235-16
Subject(s) - chlamydia trachomatis , neisseria gonorrhoeae , nucleic acid amplification tests , gonococcal infection , medicine , chlamydiaceae , chlamydiales , virology , neisseria , sexually transmitted disease , microbiology and biotechnology , biology , bacteria , human immunodeficiency virus (hiv) , genetics , syphilis
The Aptima Combo 2 (AC2) and Aptima CT (ACT) (Hologic Inc., San Diego, CA) are nucleic acid amplification tests (NAATs) that detectChlamydia trachomatis . AC2 also detectsNeisseria gonorrhoeae . Storage and temperature conditions may impact the utility of NAATs in some settings and screening programs. We evaluated specimen stability for use beyond the Aptima package insert specifications for temperature and duration of storage (between 2°C and 30°C and 60 days, respectively) in two studies: (i) dryC. trachomatis -seeded swabs were used with ACT after storage at 4°C, 23°C, or 36°C for up to 84 days and (ii) swabs seeded withC. trachomatis andN. gonorrhoeae and then placed in transport medium were tested with AC2, after being mailed via the U.S. Postal Service to three different sites. Prolonged storage of samples had no effect, and samples stored at 4°C, 23°C, and 36°C for up to 84 days yielded comparable ACT positivities, although there was a drop in signal intensity for virtually all specimens under all storage/shipping conditions after day 21. In the mailing study, 80%, 52% and 29% of seeded swabs were exposed to temperatures of >30°C during three rounds in transit, and 2% reached temperatures of >40°C. No evidence of signal degradation in the AC2 assay for detection ofC. trachomatis orN. gonorrhoeae was observed, although some mailed swabs took more than 5 weeks to reach the laboratory site. These two studies support the potential use of swabs at temperatures above 36°C and storage beyond 60 days and provide confidence regarding this commercially available NAAT for testing of specimens after mailing.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom