z-logo
open-access-imgOpen Access
Evaluation of Simplexa Group A Strep Direct Kit Compared to Hologic Group A Streptococcal Direct Assay for Detection of Group A Streptococcus in Throat Swabs
Author(s) -
Deirdre L. Church,
Tracie Lloyd,
Oscar Larios,
Daniel B. Gregson
Publication year - 2018
Publication title -
journal of clinical microbiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.349
H-Index - 255
eISSN - 1070-633X
pISSN - 0095-1137
DOI - 10.1128/jcm.01666-17
Subject(s) - throat , pharyngitis , throat culture , streptococcus , streptococcus pyogenes , medicine , real time polymerase chain reaction , group a , predictive value , veterinary medicine , microbiology and biotechnology , biology , surgery , bacteria , biochemistry , gene , genetics , staphylococcus aureus
Diagnosis of bacterial pharyngitis is confirmed by detection of group A Streptococcus (GAS) in patient throat samples. Testing of throat samples has historically relied on culture, but new molecular methods allow much faster test turnaround time (i.e., same day versus 48 to 72 h for culture). Our laboratory uses the Hologic GAS Direct (GASD) assay for screening more than 125,000 throat samples per year. Simplexa GAS Direct is a new real-time quantitative PCR (qPCR) assay that does not require initial DNA extraction. Performance of Simplexa qPCR was compared to GASD. A total of 289 throat swabs were collected from patients attending ambulatory clinics in Calgary, Alberta, Canada. A total of 60 (20.8%) of the samples were initially GAS positive by either method: 54 by both methods, 4 by Simplex qPCR alone, and 2 by GASD alone. An in-house PCR using a unique GAS primer set was used to resolve the 6 discrepant results. Overall, GASD compared to Simplexa qPCR had a sensitivity, specificity, positive predictive value, and negative predictive value of 93.1% versus 100%, 100% versus 100%, 100% versus 100%, and 98.31% versus 100%, respectively. Implementation of Simplexa qPCR in our laboratory setting would cost more but allow the high sample volume to be reported in half the time and save 0.62 medical laboratory technician (MLT) full-time equivalent (FTE). In comparison to culture, the implementation of Simplexa qPCR would save 2.79 medical laboratory assistant (MLA) FTE plus 0.94 MLT FTE. Simplexa qPCR has improved performance and diagnostic efficiency in a high-volume laboratory compared to GASD for GAS detection in throat swabs.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom