Validation of Real-Time PCR for Laboratory Diagnosis of Acanthamoeba Keratitis
Author(s) -
Paul Thompson,
Regis P. Kowalski,
Robert M. Q. Shanks,
Y. Jerold Gordon
Publication year - 2008
Publication title -
journal of clinical microbiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.349
H-Index - 255
eISSN - 1070-633X
pISSN - 0095-1137
DOI - 10.1128/jcm.00908-08
Subject(s) - acanthamoeba , acanthamoeba keratitis , taqman , real time polymerase chain reaction , microbiology and biotechnology , polymerase chain reaction , biology , dna extraction , serial dilution , virology , medicine , pathology , gene , biochemistry , alternative medicine
Confirmation of Acanthamoeba keratitis by laboratory diagnosis is the first step in the treatment of this vision-threatening disease. Two real-time PCR TaqMan protocols (the Rivière and Qvarnstrom assays) were developed for the detection of genus-specific Acanthamoeba DNA but lacked clinical validation. We have adapted these assays for the Cepheid SmartCycler II system (i) by determining their real-time PCR limits of detection and amplification efficiencies, (ii) by determining their ability to detect trophozoites and cysts, and (iii) by testing a battery of positive and negative samples. We also examined the inhibitory effects of a number of commonly used topical ophthalmic drugs on real-time PCR. The results of the real-time PCR limit of detection and amplification efficiency of the Rivière and Qvarnstrom assays were 11.3 DNA copies/10 microl and 94% and 43.8 DNA copies/10 microl and 92%, respectively. Our extraction protocol enabled us to detect 0.7 Acanthamoeba cysts/10 microl and 2.3 Acanthamoeba trophozoites/10 microl by both real-time PCR assays. The overall agreement between the assays was 97.0%. The clinical sensitivity and specificity of both real-time PCR assays based on culture were 100% (7 of 7) and 100% (37 of 37), respectively. Polyhexamethylene biguanide was the only topical drug that demonstrated PCR inhibition, with a minimal inhibitory dilution of 1/640 and an amplification efficiency of 72.7%. Four clinical samples were Acanthamoeba culture negative and real-time PCR positive. Our results indicate that both real-time PCR assays could be used to diagnose Acanthamoeba keratitis. Polyhexamethylene biguanide can inhibit PCR, and we suggest that specimen collection occur prior to topical treatment to avoid possible false-negative results.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom