Clinical Evaluation of the New High-Throughput Luminex NxTAG Respiratory Pathogen Panel Assay for Multiplex Respiratory Pathogen Detection
Author(s) -
Jonathan Hon-Kwan Chen,
Hoyin Lam,
Cyril ChikYan Yip,
Sally C. Y. Wong,
Jasper FukWoo Chan,
Edmond S.K.,
Vincent ChiChung Cheng,
Bone S. F. Tang,
KwokYung Yuen
Publication year - 2016
Publication title -
journal of clinical microbiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.349
H-Index - 255
eISSN - 1070-633X
pISSN - 0095-1137
DOI - 10.1128/jcm.00517-16
Subject(s) - multiplex , virology , pathogen , multiplex polymerase chain reaction , biology , respiratory system , respiratory tract infections , virus , subtyping , human metapneumovirus , respiratory tract , microbiology and biotechnology , polymerase chain reaction , gene , bioinformatics , biochemistry , anatomy , computer science , programming language
A broad range of viral and bacterial pathogens can cause acute respiratory tract infection. For rapid detection of a broad respiratory pathogen spectrum, multiplex real-time PCR is ideal. This study evaluated the performance of the new Luminex NxTAG Respiratory Pathogen Panel (NxTAG-RPP) in comparison with the BioFire FilmArray Respiratory Panel (FA-RP) or singleplex real-time PCR as reference. A total of 284 clinical respiratory specimens and 3 influenza A/H7N9 viral culture samples were tested. All clinical specimens were processed and analyzed in parallel using NxTAG-RPP and the reference standard method. The H7N9 viral culture samples were tested using NxTAG-RPP only. Overall, the NxTAG-RPP demonstrated ≥93% sensitivity and specificity for all respiratory targets except human coronavirus OC43 (HCoV-OC43) and HCoV-HKU1. The H7N9 virus was detected by the influenza A virus matrix gene target, while other influenza A virus subtyping gene targets in the panel remained negative. Complete concordance between NxTAG-RPP and FA-RP was observed in 98.8% (318/322) of positive results (kappa = 0.92). Substantial agreement was found for most respiratory targets, but significant differences were observed in human metapneumovirus (P = 0.001) and parainfluenza virus type 3 (P = 0.031). NxTAG-RPP has a higher sample throughput than FA-RP (96 samples versus 1 sample per run) while the turnaround times for NxTAG-RPP and FA-RP were 5 h (up to 96 samples) and 1 h (for one sample), respectively. Overall, NxTAG-RPP demonstrated good diagnostic performance for most respiratory pathogens. The high sample throughput with reasonable turnaround time of this new assay makes it a suitable multiplex platform for routine screening of respiratory specimens in hospital-based laboratories.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom