A Highly Sensitive and Subspecies-Specific Surface Antigen Enzyme- Linked Immunosorbent Assay for Diagnosis of Johne's Disease
Author(s) -
Shigetoshi Eda,
John P. Bannantine,
W. Ray Waters,
Yasuyuki Mori,
Robert H. Whitlock,
Mary C. Scott,
C. A. Speer
Publication year - 2006
Publication title -
clinical and vaccine immunology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.649
H-Index - 77
eISSN - 1556-6811
pISSN - 1556-679X
DOI - 10.1128/cvi.00148-06
Subject(s) - paratuberculosis , antigen , feces , mycobacterium avium subspecies paratuberculosis , biology , mycobacterium , microbiology and biotechnology , immunology , virology , veterinary medicine , medicine , bacteria , genetics
Johne's disease (JD), or paratuberculosis, caused by Mycobacterium avium subsp. paratuberculosis, is one of the most widespread and economically important diseases of livestock and wild ruminants worldwide. Control of JD could be accomplished by diagnosis and good animal husbandry, but this is currently not feasible because commercially available diagnostic tests have low sensitivity levels and are incapable of diagnosing prepatent infections. In this study, a highly sensitive and subspecies-specific enzyme-linked immunosorbent assay was developed for the diagnosis of JD by using antigens extracted from the surface of M. avium subsp. paratuberculosis. Nine different chemicals and various intervals of agitation by vortex were evaluated for their ability to extract the surface antigens. Various quantities of surface antigens per well in a 96-well microtiter plate were also tested. The greatest differences in distinguishing between JD-positive and JD-negative serum samples by ethanol vortex enzyme-linked immunosorbent assay (EVELISA) were obtained with surface antigens dislodged from 50 microg/well of bacilli treated with 80% ethanol followed by a 30-second interval of agitation by vortex. The diagnostic specificity and sensitivity of the EVELISA were 97.4% and 100%, respectively. EVELISA plates that had been vacuum-sealed and then tested 7 weeks later (the longest interval tested) had diagnostic specificity and sensitivity rates of 96.9 and 100%, respectively. In a comparative study involving serum samples from 64 fecal culture-positive cattle, the EVELISA identified 96.6% of the low-level fecal shedders and 100% of the midlevel and high-level shedders, whereas the Biocor ELISA detected 13.7% of the low-level shedders, 25% of the mid-level shedders, and 96.2% of the high-level shedders. Thus, the EVELISA was substantially superior to the Biocor ELISA, especially in detecting low-level and midlevel shedders. The EVELISA may form the basis for a highly sensitive and subspecies-specific test for the diagnosis of JD.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom