Development of a Reverse Transcription-Quantitative PCR System for Detection and Genotyping of Aichi Viruses in Clinical and Environmental Samples
Author(s) -
Masaaki Kitajima,
Akihiko Hata,
Teruo Yamashita,
Eiji Haramoto,
Hiroko Minagawa,
Hiroyuki Katayama
Publication year - 2013
Publication title -
applied and environmental microbiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.552
H-Index - 324
eISSN - 1070-6291
pISSN - 0099-2240
DOI - 10.1128/aem.00820-13
Subject(s) - genotyping , reverse transcriptase , biology , reverse transcription polymerase chain reaction , virology , real time polymerase chain reaction , computational biology , genetics , polymerase chain reaction , genotype , gene , gene expression
Aichi viruses (AiVs) have been proposed as a causative agent of human gastroenteritis potentially transmitted by fecal-oral routes through contaminated food or water. In the present study, we developed a TaqMan minor groove binder (MGB)-based reverse transcription-quantitative PCR (RT-qPCR) system that is able to quantify AiVs and differentiate between genotypes A and B. This system consists of two assays, an AiV universal assay utilizing a universal primer pair and a universal probe and a duplex genotype-specific assay utilizing the same primer pair and two genotype-specific probes. The primers and probes were designed based on multiple alignments of the 21 available AiV genome sequences containing the capsid gene. Using a 10-fold dilution of plasmid DNA containing the target sequences, it was confirmed that both assays allow detection and quantification of AiVs with a quantitative range of 1.0 × 10(1) to 1.0 × 10(7) copies/reaction, and the genotype-specific assay reacts specifically to each genotype. To validate the newly developed assays, 30 clinical stool specimens were subsequently examined with the assays, and the AiV RNA loads were determined to be 1.4 × 10(4) to 6.6 × 10(9) copies/g stool. We also examined 12 influent and 12 effluent wastewater samples collected monthly for a 1-year period to validate the applicability of the assays for detection of AiVs in environmental samples. The AiV RNA concentrations in influent and effluent wastewater were determined to be up to 2.2 × 10(7) and 1.8 × 10(4) copies/liter, respectively. Our RT-qPCR system is useful for routine diagnosis of AiVs in clinical stool specimens and environmental samples.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom