z-logo
open-access-imgOpen Access
Effects of Oritavancin on Coagulation Tests in the Clinical Laboratory
Author(s) -
Adam Belley,
Richard A. Robson,
John L. Francis,
Dorothy M. Adcock,
Stefan Tiefenbacher,
Christopher M. Rubino,
Greg Moeck,
David Sylvester,
Michael N. Dudley,
Jeffery S. Loutit
Publication year - 2016
Publication title -
antimicrobial agents and chemotherapy
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.07
H-Index - 259
eISSN - 1070-6283
pISSN - 0066-4804
DOI - 10.1128/aac.01968-16
Subject(s) - partial thromboplastin time , prothrombin time , thrombin time , medicine , pharmacology , activated clotting time , bleeding time , coagulation , heparin , chemistry , platelet , platelet aggregation
Previous studies have shown that some lipoglycopeptide and lipopeptide antimicrobial agents may cause falsely elevated values for some phospholipid-dependent coagulation tests. The effect of oritavancin, a lipoglycopeptide antibiotic, on coagulation test results was explored using pooled human plasma samples spiked with drug and in a clinical study after an infusion of a single 1,200-mg intravenous dose of oritavancin in normal healthy volunteers. Pooled plasma with oritavancin addedex vivo showed concentration-dependent prolongation of prothrombin time/international normalized ratio (PT/INR), activated partial thromboplastin time (aPTT), and dilute Russell viper venom time (DRVVT) test results. In contrast, oritavancin had no effect on the activated protein C resistance assay, chromogenic anti-factor Xa assay (anti-FXa), thrombin time, and an immunoassay for the laboratory diagnosis of heparin-induced thrombocytopenia. In participants that received a single dose of oritavancin, elevations in PT/INR result, aPTT, DRVVT, activated clotting time, and silica clotting time occurred, with the maximum times to resolution of test interference determined to be 12, 120, 72, 24, and 18 h, respectively. The anti-FXa assay was unaffected, whereas transient elevations in D dimer levels were observed in 30% of participants, with a maximum time to resolution of 72 h. Although oritavancin has no impact on the coagulation systemin vivo , a single dose of oritavancin can produce falsely elevated values of some coagulation tests used to monitor hemostasis. The interference of oritavancin on affected tests is transient, and the test results revert to normal ranges within specified times after dosing.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom