z-logo
open-access-imgOpen Access
Clinical studies of biceps anisotropy, relaxation and nonlinearity with a medical device for ultrasonic imaging
Author(s) -
Timofey Krit,
Mariya Begicheva,
Yuly Kamalov,
В. Г. Андреев
Publication year - 2018
Publication title -
proceedings of meetings on acoustics
Language(s) - English
Resource type - Conference proceedings
ISSN - 1939-800X
DOI - 10.1121/2.0000923
Subject(s) - biceps , ultrasonic sensor , materials science , anisotropy , shear modulus , shear (geology) , modulus , ultrasound , acoustics , composite material , optics , physics , anatomy , medicine
We applied a commercial ultrasonic clinical diagnostic system for studies of human biceps. The investigated area was visualized in B-mode at a frequency of 8 MHz. We selected 1 cm and 2.5 cm depths for shear wave excitation. On these depths, the focused ultrasonic wave caused the acoustical radiation force. Due to nonlinear mechanism of excitation, a shear wave arose. The results we have obtained show that the biceps have the shear moduli of the order of 10 kPa. The loaded biceps demonstrated the nonlinear behavior better pronounced for the volunteer with smaller body mass index (BMI). As the load on the biceps increases, the shear modulus measured along the muscle fibers grows. The observed growth was stronger for the shear modulus of the short head. The shear modulus, measured in the direction across the fibers of the biceps, does not depend on the magnitude of the applied load and remains at the unloaded value. In 1 minute after load is removed the biceps tend to relax and its shear moduli turn their initial values.We applied a commercial ultrasonic clinical diagnostic system for studies of human biceps. The investigated area was visualized in B-mode at a frequency of 8 MHz. We selected 1 cm and 2.5 cm depths for shear wave excitation. On these depths, the focused ultrasonic wave caused the acoustical radiation force. Due to nonlinear mechanism of excitation, a shear wave arose. The results we have obtained show that the biceps have the shear moduli of the order of 10 kPa. The loaded biceps demonstrated the nonlinear behavior better pronounced for the volunteer with smaller body mass index (BMI). As the load on the biceps increases, the shear modulus measured along the muscle fibers grows. The observed growth was stronger for the shear modulus of the short head. The shear modulus, measured in the direction across the fibers of the biceps, does not depend on the magnitude of the applied load and remains at the unloaded value. In 1 minute after load is removed the biceps tend to relax and its shear moduli turn their i...

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom