Surface functionalisation of TiO2 evanescent waveguide sensor for E.coli monitoring
Author(s) -
Agung Purniawan,
G. Pandraud,
Konstantinos A. Vakalopoulos,
Pim J. French,
P.M. Sarro
Publication year - 2012
Publication title -
proceedings of spie, the international society for optical engineering/proceedings of spie
Language(s) - English
Resource type - Conference proceedings
SCImago Journal Rank - 0.192
H-Index - 176
eISSN - 1996-756X
pISSN - 0277-786X
DOI - 10.1117/12.922498
Subject(s) - waveguide , materials science , biosensor , photodiode , atomic layer deposition , monolayer , surface modification , plasma enhanced chemical vapor deposition , substrate (aquarium) , layer (electronics) , surface acoustic wave , optoelectronics , diode , nanotechnology , chemical vapor deposition , optics , chemical engineering , oceanography , physics , geology , engineering
This work reports the surface functionalisation of evanescent waveguide sensors to immobilise E. coli. In biosensors, the surface functionalisation is an important treatment to ensure that the sensor properly detects the cells of interest. In this paper, we study the thin film surface functionalisation of a TiO2 evanescent waveguide sensor and their effect on light transmission for the early detection of E. coli in post colon surgery. TiO2 deposited using atomic layer deposition (ALD) is used as waveguide material. Four layers are used in the functionalisation : the self-assembled monolayer (SAM), the protein, 1-ethyl-3-(3-dimethylaminopropyl) (EDC) and the antibodies. Aminopropyltriethoxysilane (APTES) is used as SAM and reacts with -OH group (hydroxyl). The -OH group must be provided on substrate. In order to have the proper -OH group we deposited 10 nm SiO2 on the waveguides using PECVD and then treated the samples in oxygen plasma chamber for 2 minutes to create the groups. Afterward APTES is immediately applied on the surface after every layers of the functionalisation process. The second layer (Protein A) of the functionalisation is then put on APTES as interlayer. EDC is used as crosslink agent between APTES and antibodies. The light of Superluminescent light emitting diodes (SLEDs) (λ = 1.3 μm, 400 mA) is channelled using an optical fibre into the functionalised waveguides. The transmitted light is measured with a photodiode. The sensitivity of the sensor was evaluated using several different drain fluid concentrations in medium.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom