z-logo
open-access-imgOpen Access
A fast scatter field estimator for digital breast tomosynthesis
Author(s) -
Oliver Díaz,
David R. Dance,
Kenneth C. Young,
Premkumar Elangovan,
Predrag R. Bakić,
Kevin Wells
Publication year - 2012
Publication title -
proceedings of spie, the international society for optical engineering/proceedings of spie
Language(s) - English
Resource type - Conference proceedings
SCImago Journal Rank - 0.192
H-Index - 176
eISSN - 1996-756X
pISSN - 0277-786X
DOI - 10.1117/12.911494
Subject(s) - monte carlo method , imaging phantom , detector , estimator , tomosynthesis , projection (relational algebra) , mammography , optics , computer science , physics , mathematics , algorithm , statistics , medicine , cancer , breast cancer
Digital breast tomosynthesis (DBT) is a promising alternative approach to overcome the limitations of tissue superposition found in full-field 2D digital mammography. However, due to the absence of anti-scatter grids in DBT, accurate scatter estimation for each projection is necessary for modelling the image reconstruction stage. In this work we identify the limitations associated with scatter estimation using spatial invariant scatter kernels, in particular at the edge region where such methods result in scatter overestimation. Such approaches show an overestimation of scatter-to-primary ratio of over 50% at the edges when compared with results from direct Monte Carlo simulation. This problem was found to increase with projection angle. Simulation work presented here shows that this overestimation in scatter is largely due to air gap between the lower curved breast edge and the detector. We propose a new fast, accurate scatter field estimator for use in DBT which not only considers the breast thickness and primary incidence angle, but also accounts for scatter exiting the breast edge region and traversing an air gap prior to absorption in the detector. The new proposed scatter estimator represents an alternative approach to this problem which reduces discrepancies at the edge of a breast phantom. Moreover, the time required for generating scatter has dropped from approximately 12 hours using Monte Carlo simulations for 1010 photons to just a few minutes per projection. The insertion of scatter from the compression paddle to aforementioned methodologies is also discussed.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom