z-logo
open-access-imgOpen Access
Simulation of a miniature, low-power time-of-flight mass spectrometer for in situ analysis of planetary atmospheres
Author(s) -
Todd King,
Stephanie Getty,
Patrick A. Roman,
F. A. Herrero,
Hollis H. Jones,
Duncan M. Kahle,
Bernard A. Lynch,
George Suárez,
W. B. Brinckerhoff,
Paul Mahaffy
Publication year - 2008
Publication title -
proceedings of spie, the international society for optical engineering/proceedings of spie
Language(s) - English
Resource type - Conference proceedings
SCImago Journal Rank - 0.192
H-Index - 176
eISSN - 1996-756X
pISSN - 0277-786X
DOI - 10.1117/12.780113
Subject(s) - reflectron , mass spectrometry , time of flight , spectrometer , physics , optics , materials science , ionization , time of flight mass spectrometry , ion , quantum mechanics
We are implementing nano- and micro-technologies to develop a miniaturized electron impact ionization mass spectrometer for planetary science. Microfabrication technology is used to fabricate the ion and electron optics, and a carbon nanotube (CNT) cathode is used to generate the ionizing electron beam. Future NASA planetary science missions demand miniaturized, low power mass spectrometers that exhibit high resolution and sensitivity to search for evidence of past and present habitability on the surface and in the atmosphere of priority targets such as Mars, Titan, Enceladus, Venus, Europa, and short-period comets. Toward this objective, we are developing a miniature, high resolution reflectron time-of-flight mass spectrometer (Mini TOF-MS) that features a low-power CNT field emission electron impact ionization source and microfabricated ion optics and reflectron mass analyzer in a parallel-plate geometry that is scalable. Charged particle electrodynamic modeling (SIMION 8.0.4) is employed to guide the iterative design of electron and ion optic components and to characterize the overall performance of the Mini TOF-MS device via simulation. Miniature (< 1000 cm3) TOF-MS designs (ion source, mass analyzer, detector only) demonstrate simulated mass resolutions > 600 at sensitivity levels on the order of 10-3 cps/molecule N2/cc while consuming 1.3 W of power and are comparable to current spaceflight mass spectrometers. Higher performance designs have also been simulated and indicate mass resolutions ~1000, though at the expense of sensitivity and instrument volume.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom