A Reconfigurable Multiplanar In Vitro Simulator for Real-Time Absolute Motion With External and Musculotendon Forces
Author(s) -
Joshua T. Green,
Rena F. Hale,
Jérôme Hausselle,
Roger V. Gonzalez
Publication year - 2017
Publication title -
journal of biomechanical engineering
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.546
H-Index - 126
eISSN - 1528-8951
pISSN - 0148-0731
DOI - 10.1115/1.4037853
Subject(s) - squat , kinematics , simulation , ground reaction force , actuator , torque , control theory (sociology) , repeatability , controller (irrigation) , engineering , biomechanics , computer science , mathematics , physics , physiology , agronomy , statistics , electrical engineering , control (management) , classical mechanics , artificial intelligence , biology , thermodynamics
Advancements in computational musculoskeletal biomechanics are constrained by a lack of experimental measurement under real-time physiological loading conditions. This paper presents the design, configuration, capabilities, accuracy, and repeatability of The University of Texas at El Paso Joint Load Simulator (UTJLS) by testing four cadaver knee specimens with 47 real-time tests including heel and toe squat maneuvers with and without musculotendon forces. The UTJLS is a musculoskeletal simulator consisting of two robotic manipulators and eight musculotendon actuators. Sensors include eight tension load cells, two force/torque systems, nine absolute encoders, and eight incremental encoders. A custom control system determines command output for position, force, and hybrid control and collects data at 2000 Hz. Controller configuration performed forward-dynamic control for all knee degrees-of-freedom (DOFs) except knee flexion. Actuator placement and specimen potting techniques uniquely replicate muscle paths. Accuracy and repeatability standard deviations across specimen during squat simulations were equal or less than 8 N and 5 N for musculotendon actuators, 30 N and 13 N for ground reaction forces (GRFs), and 4.4 N·m and 1.9 N·m for ground reaction moments. The UTJLS is the first of its design type. Controller flexibility and physical design support axis constraints to match traditional testing rigs, absolute motion, and synchronous real-time simulation of multiplanar kinematics, GRFs, and musculotendon forces. System DOFs, range of motion, and speed support future testing of faster maneuvers, various joints, and kinetic chains of two connected joints.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom