Measurements of heat transfer from an array of vertical heater rods to the walls of a square, helium-filled enclosure are performed for a range of enclosure temperatures, helium pressures, and rod heat generation rates. This configuration is relevant to a used nuclear fuel assembly within a dry storage canister. The measurements are used to assess the accuracy of computational fluid dynamics (CFD)/radiation simulations in the same configuration. The simulations employ the measured enclosure temperatures as boundary conditions and predict the temperature difference between the rods and enclosure. These temperature differences are as large as 72 C for some experiments. The measured temperature of rods near the periphery of the array is sensitive to small, uncontrolled variations in their location. As a result, those temperatures are not as useful for validating the simulations as measurements from rods near the array center. The simulated rod temperatures exhibit random differences from the measurements that are as large as 5.7 C, but the systematic (average) error is 1 C or less. The random difference between the simulated and measured maximum array temperature is 2.1 C, which is less than 3% of the maximum rod-to-wall temperature difference. [DOI: 10.1115/1.4037493]
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom