Monopolar Electrosurgical Thermal Management System to Reduce Lateral Thermal Damage During Surgery
Author(s) -
Robert E. Dodde,
Jacob S. Gee,
James D. Geiger,
Albert J. Shih
Publication year - 2010
Publication title -
journal of medical devices
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.242
H-Index - 29
eISSN - 1932-619X
pISSN - 1932-6181
DOI - 10.1115/1.3439653
Subject(s) - materials science , resistive touchscreen , biomedical engineering , finite element method , thermal , ex vivo , in vivo , computer science , medicine , structural engineering , physics , microbiology and biotechnology , meteorology , engineering , computer vision , biology
A monopolar electrosurgical device is the most commonly used energy-based surgical instrument. Monopolar devices are primarily applied to incise, ablate, dissect, and coagulate tissue by transferring electrical energy to the tissue in the form of heat generation through resistive heating. The substantial amount of heat created by the monopolar device has been shown to spread throughout the tissue, creating unintended tissue damage, which can lead to nerve thermal damage and loss of normal bodily functions. Due to this fact, energy-based devices have had a limited use in surgical procedures performed near neurovascular bundles. The extent to which the generated heat raises the temperature of the surrounding tissue is referred to as the device’s thermal spread. In this study, ex vivo and in vivo experiments have shown that a novel thermal management system (TMS) can reduce the amount of thermal spread created by a typical monopolar device, thus eliminating the thermal collateral tissue damage typically caused during a monopolar procedure. The incorporation of a TMS consisting of adjacent cooling channels reduces the thermal spread of the device, as illustrated in a reduction as high as 50% in the maximum temperature recorded during an in vivo experimental procedure. The design of the TMS was aided by finite element modeling (FEM). The phenomenon of monopolar resistive heating was modeled to analyze the temperature distributions in biological tissue subjected to heat generation by a commonly used monopolar electrosurgical device. The mathematical model was verified by comparing the model’s predicted temperature distribution with experimental results. Ex vivo experiments were performed with liver tissue heated by a monopolar pencil electrode. The experimental data for 1 mm distance from the electrode are seen to fit within 1% of the predicted temperature values by the FEM simulation.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom