Effects of Design Parameters on the Sensitivity of a Micro-Cantilever Based Biosensor
Author(s) -
S. Vidhya,
Leny Mathew
Publication year - 2009
Publication title -
journal of medical devices
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.242
H-Index - 29
eISSN - 1932-619X
pISSN - 1932-6181
DOI - 10.1115/1.3136843
Subject(s) - cantilever , piezoresistive effect , biosensor , materials science , deflection (physics) , surface stress , sensitivity (control systems) , resistive touchscreen , nanotechnology , microelectromechanical systems , analyte , optoelectronics , electronic engineering , chemistry , composite material , optics , electrical engineering , physics , engineering , surface energy
Piezo-resistive actuation of a microcantilever induced by biomolecular binding such as DNA hybridization and antibody-antigen binding is an important principle useful in biosensing applications. As the magnitude of the forces exerted is small, increasing the sensitivity of the microcantilever becomes critical. In this paper, we are considering to achieve this by geometric variation of the cantilever. The sensitivity of the cantilever was improved so that the device can sense the presence of antigen even if the magnitude of surface-stresses over the microcantilever was very small. We consider a `T-shaped' cantilver that eliminates the disadvantages while improving the sensitivity simultaneously. Simulations for validation have been performed using Intellisuite software (a MEMS design and simulation package). The simulations reveal that the T-shaped microcantilver is almost as sensitive as a thin cantilever and has relatively very low buckling effect. Simulations also reveal that with an increase in thickness of the cantilever, there is a proportional decrease in the sensitivity. This paper presents an analytical modeling and simulation studies of a piezoresistive cantilever used as MEMS based biosensor for the detection of cardiac markers. Diagnosis of Myocardial Infarction was achieved by the nanomechanical deflection of the microcantilever due to adsorption of the Troponin I complex. The deflection of the microcantilever was measured in terms of the piezoresistive changes by implanting boron at the anchor point where there is maximum strain due to the adsorption of the analyte molecules. The biochemical interactions between the Cardiac Troponin I (cTnl) complex and the immobilized antibodies would cause change in resistance of the piezoresistor integrated at the anchor point. A ‘T’ shaped microcantilever design was proposed for the study. The distal end of the device was coated with gold. The sensitivity of the cantilever was improved so that the device can sense the presence of antigen even if the magnitude of surface-stresses over the microcantilever was very small. To obtain an application specific optimum design parameter and predict the cantilever performance. The miniaturization of the cantilever-based biosensor leads to significant advantages in the absolute device sensitivity.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom