z-logo
open-access-imgOpen Access
Interchangeable Range of Ozone Concentration Simulation for Low Cost Reconfigurable Brass Gas Cell
Author(s) -
Tay Ching En Marcus,
Michael David,
Maslina Yaacob,
Mohd Rashidi Salim,
Mohd Haniff Ibrahim,
Nor Hafizah Ngajikin,
Asrul Izam Azmi,
Sevia Mahdaliza Idrus,
Zolkafle Buntat
Publication year - 2014
Publication title -
jurnal teknologi
Language(s) - English
Resource type - Journals
eISSN - 2180-3722
pISSN - 0127-9696
DOI - 10.11113/jt.v69.3289
Subject(s) - transmittance , path length , ozone , brass , range (aeronautics) , optical path , materials science , ultraviolet , analytical chemistry (journal) , mean free path , optical path length , absorption (acoustics) , wavelength , optics , optoelectronics , chemistry , physics , scattering , environmental chemistry , organic chemistry , copper , metallurgy , composite material
Ultraviolet absorption spectroscopy is reliable for ozone concentration measurement. Concentration range and optical path length are inversely related based on theoretical calculation and observation of previous work. However, gas cells for ozone application are typically not expandable. In addition, they incur cost for custom fabrication. Here we design a reconfigurable brass gas cell that may interchange optical path length between 5.6 cm and 10.8 cm. Components are available at low cost, easy to joint and ready to use. Theoretical background and gas cell structure are discussed. Practical transmittance values between e -0.65 and e -0.05 are proposed for theoretical calculation of concentration via Beer-Lambert law. The concentration values are used in SpectralCalc.com gas cell simulation to obtain transmittance. Both approaches yield comparable result. Simulation result shows concentration range of 5.6 cm optical path length gas cell ( 31.82 ppm to 413.67 ppm ) is wider than concentration range of 10.8 cm optical path length gas cell ( 16.50 ppm to 214.49 ppm ). Simulation condition is at transmittance from 0.5291 to 0.9522, sampling wavelength 253.65 nm, temperature 300 K and pressure 1 atm. Thus, we strongly recommend short optical path length gas cell (5.6 cm) for wide range of concentration measurement ( 31.82 ppm to 413.67 ppm ).

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom