z-logo
open-access-imgOpen Access
Novel Logarithmic Reference Free Adaptive Signal Enhancers for ECG Analysis of Wireless Cardiac Care Monitoring Systems
Author(s) -
Md. Nizamuddin Salman,
Polipalli Trinatha Rao,
Md. Zia Ur Rahman
Publication year - 2018
Publication title -
ieee access
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.587
H-Index - 127
ISSN - 2169-3536
DOI - 10.1109/access.2018.2866303
Subject(s) - aerospace , bioengineering , communication, networking and broadcast technologies , components, circuits, devices and systems , computing and processing , engineered materials, dielectrics and plasmas , engineering profession , fields, waves and electromagnetics , general topics for engineers , geoscience , nuclear engineering , photonics and electrooptics , power, energy and industry applications , robotics and control systems , signal processing and analysis , transportation
In remote cardiac care monitoring applications, electrocardiogram (ECG) signals are contaminated by artifacts during data acquisition and transmission of signals. The removal of the artifacts is an important task for proper diagnosis. In this paper, an attempt has been made to remove the artifacts, especially baseline wander (BW), muscle artifacts (MA), power line interference (PLI), and electrode motion (EM) using a least mean logarithmic squares (LMLS) algorithm. Further to improve the filtering ability and speed up the convergence process, data normalization is applied. The above algorithm can be normalized with reference to maximum data normalization which leads to reduced computational complexity in the denominator. Based on the above algorithms, various adaptive signal enhancers (ASE's) are developed. To reduce the computational complexity of the signal enhancer, the proposed ASE's are combined with sign-based algorithms. The proposed ASE's are tested on real ECG signals obtained from the MIT-BIH database to compare the performance. The simulation results obtained illustrate that the block-based algorithms are better than LMLS in terms of the signal to noise ratio (SNR), excess mean square error, and computational complexity. Among the LMLS variants, the BB-SRNLMLS-based ASE's have better filtering ability with a reduced number of computations. The improvement of the SNR achieved in the process through the use of BB-SRNLMLS-based ASE's are calculated as 13.2945 dBs, 12.4589 dBs, 16.4289 dBs, and 13.6423 dBs, respectively, for BW, MA, PLI, and EM artifacts.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom